ACSR Duck Aluminum Conductor Steel Reinforced 605MCM Overhead Bare Conductor
ACSR Duck Aluminum Conductor Steel Reinforced 605MCM Overhead Bare Conductor image
Brand Name :
Zhenglan Cable
Model Number :
Aluminum conductor steel reinforced ACSR Duck 605MCM Overhead bare conductor
Certification :
ISO 9001, ISO14001, ISO45001
Place of Origin :
HN, CN
MOQ :
3ton
Price :
0.1-100USD/m
Payment Terms :
L/C, T/T,
Supply Ability :
15ton/day
Delivery Time :
depends on quantity
Packaging Details :
Wooden drum, wood iron drum
Material :
aluminum, ganvalnized steel wire
Insulation :
None
Cable Drum Length :
Normal or Customized
characted :
Bare Conductor
Port :
Tianjin or Qingdao port
Standard :
IEC61089, ASTM B232/232M
Aluminum conductor steel reinforced ACSR Duck 605MCM Overhead bare conductor
Application
Aluminum conductor steel reinforced ACSR Duck 605MCM Overhead bare conductor are commonly for river crossings, overhead earth wires, and installations involving extra-long spans use as bare overhead transmission cable and as primary and secondary distribution cable. They have a long service record because of its economy, dependability, and strength to weight ratio.
Bare Conductor Electrical Cable STANDARD
Basic design to BS 215-2 / BS EN 50182 / IEC 61089 / ASTM B 232/B 232M / DIN 48204 / JIS C 3110 standards.
Note: The values of current rating mentioned in above Table are based on wind velocity of 0.6 metre/second, solar heat radiation of 1200 watt/metre2, ambient temperature of 50° C & conductor temperature of 80°C.
Bare Conductor Electrical Cable CONSTRUCTION
ACSR conductors are formed by several wires of aluminium and galvanized steel, stranded in concentric layers. The core wire or wires are made of galvanized steel and the external layer or layers. Galvanized steel core consist normally of 1, 7 or 19 wires. The diameters of steel and aluminium wires can be the same, or different.
By varying the relative proportions of aluminium and steel, the required characteristics for any particular application can be reached. A higher U. T. S. Can be obtained, by increasing steel content, and a higher current carrying capacity by increasing aluminium content.
ELECTRICAL PROPERTIES
density@20ºC | Aluminium: 2.703 kg/dm |
Galvanised Steel: 7.80 kg/dm | |
Temperature Coefficient@20°C | Aluminium: 0.00403 (°C) |
resistivity@20°C | Aluminium: Should not exceed 0.028264 |
linear Expansivity |
Aluminium: 23 x10 (°C) |
Galvanised Steel: 11.5 x10 (1/°C) |
SERVICE CONDITIONS
Ambient Temperature | -5°C – 50°C |
Wind Pressure | 80 – 130kg/m |
Seismic Acceleration | 0.12 – 0.05g |
Isokeraunic level | 10 – 18 |
relative Humidity | 5 – 100% |
TECHNICAL DATA
Numbers of Wires | Modules of Elasticity | Coeficient of linear Expansion | |||
AL | STEEL | Kg/mm2 | Lb/in2 | 1/Cº | 1/Fº |
6 | 1 | 81 | 11.5 x106 | 19.1 x10-6 | 10.6 x10-6 |
6 | 7 | 77 | 11.0 x106 | 19.8 x10-6 | 11.0 x10-6 |
12 | 7 | 107 | 15.2 x106 | 15.3 x10-6 | 8.5 x10-6 |
18 | 1 | 67 | 9.5 x106 | 21.2 x10-6 | 11.8 x10-6 |
24 | 7 | 74 | 10.5 x106 | 19.6 x10-6 | 10.9 x10-6 |
26 | 7 | 77 | 10.9 x106 | 18.9 x10-6 | 10.5 x10-6 |
28 | 7 | 79 | 11.2 x106 | 18.4 x10-6 | 10.2 x10-6 |
30 | 7 | 82 | 11.6 x106 | 17.8 x10-6 | 9.9 x10-6 |
30 | 19 | 80 | 11.4 x106 | 18.0 x10-6 | 10.0 x10-6 |
32 | 19 | 82 | 11.7 x106 | 17.5 x10-6 | 9.7 x10-6 |
54 | 7 | 70 | 9.9 x106 | 19.3 x10-6 | 10.7 x10-6 |
54 | 19 | 68 | 9.7 x106 | 19.4 x10-6 | 10.8 x10-6 |
Aluminum conductor steel reinforced ACSR Duck 605MCM Overhead bare conductor Parameters
AMERICAN STANDARD ASTM B232-B232 M1999 | ||||||||
Code Word | Stranding | Stranding | Nominal Overall Diameter | Mass | Rated Strength | |||
Aluminium Wires | Steel Wires | |||||||
Number | Diameter | Number | Diameter | |||||
mm | mm | mm | kg/Km | kN | ||||
Raven | 6/1 | 6 | 3.37 | 1 | 3.37 | 10.11 | 216.08 | 19.48 |
Minorca | 12/7 | 12 | 2.44 | 7 | 2.44 | 12.22 | 411.18 | 50.26 |
Quail | 6/1 | 6 | 3.78 | 1 | 3.78 | 11.35 | 272.04 | 23.58 |
Leghorn | 12/7 | 12 | 2.69 | 7 | 2.69 | 13.46 | 499.28 | 60.5 |
Guinea | 12/7 | 12 | 2.92 | 1 | 2.92 | 14.63 | 589.76 | 71.17 |
Pigeon | 6/1 | 6 | 4.25 | 1 | 4.25 | 12.75 | 343.02 | 29.45 |
Dotterel | 12/7 | 12 | 3.08 | 7 | 3.08 | 15.42 | 656.13 | 76.95 |
Dorking | 12/7 | 12 | 3.2 | 7 | 3.2 | 16.03 | 707.92 | 83.18 |
Brahma | 16/19 | 16 | 2.86 | 19 | 2.48 | 18.14 | 1003.91 | 126.33 |
Cochin | 12/7 | 12 | 3.37 | 7 | 3.37 | 16.87 | 783.96 | 92.08 |
Penguin | 6/1 | 6 | 4.77 | 1 | 4.77 | 14.3 | 432.76 | 37.14 |
Partidge | 26/7 | 26 | 2.57 | 7 | 2 | 16.31 | 546.01 | 50.26 |
Waxwing | 18/1 | 18 | 3.09 | 1 | 3.09 | 15.47 | 430.23 | 30.69 |
Ostrich | 26/7 | 26 | 2.73 | 7 | 2.12 | 17.27 | 613.42 | 56.49 |
Oriole | 30/7 | 30 | 2.69 | 1 | 2.69 | 18.82 | 783.37 | 76.95 |
Linnet | 26/7 | 26 | 2.89 | 7 | 2.25 | 18.29 | 687.53 | 62.72 |
Widgeon | 18/1 | 18 | 3.47 | 1 | 3.47 | 17.37 | 542.88 | 38.7 |
Lark | 30/7 | 30 | 2.92 | 7 | 2.92 | 20.47 | 925.34 | 90.3 |
Ibis | 26/7 | 26 | 3.14 | 7 | 2.44 | 19.89 | 812.54 | 72.51 |
- overhead transmission line use bare conductor(ACSR, AAC, AAAC etc)
- 1-35kv overhead transmission line use insulated conductor
- power distribution use 0.6/1kv, 1.8/3kv PVC/XLPE/PE insulated LV(low voltage) power cable armored or unarmored
- power distribution use 3.6/6kv, 6/10kv,8.7/10kv, 8.7/15kv, 12/20kv, 21/35kv, 26/35kv XLPE insulated MV(medium voltage) power cable armored or unarmored;
- 300/300V, 300/500V, 450/750V cotrol cable, house wire
We are China ACSR Duck Aluminum Conductor Steel Reinforced 605MCM Overhead Bare Conductor manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Tags: 605MCM Overhead Bare Conductor, ACSR Duck Aluminum Conductor Steel Reinforced, Aluminum Conductor Steel Reinforced, Aluminum Conductor Steel Reinforced 605MCMFAST AND RELIABLE SERVICE FOR YOUR PROJECT
Contact our trained experts today to find your perfect power solution.