ACSR Abc Bundle Conductor AAC Aerial Bundle Conductor Cable
ACSR Abc Bundle Conductor AAC Aerial Bundle Conductor Cable image
Brand Name :
SANWU
Model Number :
ABC-1/0AWG
Certification :
CCC,ISO
Place of Origin :
LUOYANG, CHINA
MOQ :
1000m
Price :
Negote
Payment Terms :
T/T, L/C
Supply Ability :
200T/day
Delivery Time :
7-15 days
Packaging Details :
Wooden drums
Conductor :
ACSR AAC
Conductor type :
Solid/7 strands
Cores :
2 cores, duplex
Insulated :
one bare, one insulated
Conductor size :
1/0AWG
Insulation :
XLPE/PE/PVC
Voltage :
0.6/1.0V
ACSR Abc Bundle Conductor AAC Aerial Bundle Conductor Cable
Abc Bundle Conductor has a working temperature range from -40℃ to +80℃ and can be set up in temperatures as low as -20°C.
Our standard of Low Voltage ABC (lv abc cable) is m BS7870 and has a voltage rating of 0.6/1kV. With the insulation, it also meets Class II according to IEC 61140 in protecting against electric shock.
1. Duplex Service Drop-Aluminum Conductor
Construction:
Concentric strand or compressed 1350-H19 conductor, polyethylene or crosslinked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy neutral messenger.
Standards: ASTM B-230, B-231, B-232 and B-399 & ICEA S-76-474
Code Name |
Phase Conductor | Bare Neutral Messenger | Weight Per 1000 ft(lbs) |
Rating(Amps) | ||||||
Size AWG |
Strand | Insulation thickness (mls) |
Size AWG |
*Strand | Breaking strength (lbs) |
XLP | POLY | XLP | POLY | |
AAC | ||||||||||
Pekingese | 6 | solid | 45 | 6 | 7/w | 563 | 63.5 | 61.7 | 70 | 70 |
Collie | 6 | 7/w | 45 | 6 | 7/w | 563 | 66.8 | 63.1 | 70 | 70 |
Dachshund | 4 | solid | 45 | 4 | 7/w | 881 | 95.5 | 93.4 | 90 | 90 |
Spaniel | 4 | 7/w | 45 | 4 | 7/w | 881 | 100.5 | 95.4 | 90 | 90 |
Doberman | 2 | 7/w | 45 | 2 | 7/w | 1,350 | 152.7 | 145.7 | 120 | 120 |
Malemute | 1/0 | 19/w | 60 | 1/0 | 7/w | 1,990 | 242.6 | 234.2 | 160 | 160 |
ACSR NEUTRAL-MESSENGER | ||||||||||
Setter | 6 | solid | 45 | 6 | 6/1 | 1.190 | 75.0 | 73.2 | 70 | 70 |
Shepherd | 6 | 7/w | 45 | 6 | 6/1 | 1.190 | 78.3 | 74.6 | 70 | 70 |
Eskimo | 4 | solid | 45 | 4 | 6/1 | 1.860 | 113.7 | 111.6 | 90 | 90 |
Terrier | 4 | 7/w | 45 | 4 | 6/1 | 1.860 | 118.7 | 113.6 | 90 | 90 |
Chow | 2 | 7/w | 45 | 2 | 6/1 | 2.850 | 181.7 | 174.7 | 120 | 120 |
Bull | 1/0 | 19/w | 60 | 1/0 | 6/1 | 4.380 | 288.7 | 280.3 | 160 | 160 |
6201 ALLOY NEUTRAL-MESSENGER | ||||||||||
Chihuahua | 6 | solid | 45 | 6 | 7/w | 1,110 | 67.6 | 65.8 | 70 | 70 |
Vizsla | 6 | 7/w | 45 | 6 | 7/w | 1,110 | 70.9 | 67.2 | 70 | 70 |
Harrier | 4 | solid | 45 | 4 | 7/w | 1,760 | 102.0 | 99.9 | 90 | 90 |
Whippet | 4 | 7/w | 45 | 4 | 7/w | 1,760 | 107.0 | 101.9 | 90 | 90 |
Schnauzer | 2 | 7/w | 45 | 2 | 7/w | 2,800 | 163.3 | 156.2 | 120 | 120 |
Heeler | 1/0 | 19/w | 60 | 1/0 | 7/w | 4,460 | 259.2 | 250.8 | 160 | 160 |
2. Triplex Service Drop-Aluminum Conductor
Construction:
Concentric strand or compressed 1350-H19 conductor, polyethylene or crosslinked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy neutral messenger.
Standards: ASTM B-230, B-231, B-232 and B-339 & ICEA S-76-474
Code Name |
Phase Conductor | Bare Neutral Messenger | Weight Per 1000 ft(lbs) |
Ampacity (Amps) | |||||||
Size AWG |
Stranding | Insulation thickness (mls) |
Size AWG |
Stranding | Breaking strength (lbs) |
XLP | POLY | XLP | POLY | ||
6201 ALLOY NEUTRAL-MESSENGER | |||||||||||
Minex | 6 | solid | 45 | 6 | 7 | 1,110 | 106.6 | 102.9 | 85 | 70 | |
Hippa | 6 | 7/w | 45 | 6 | 7 | 1,110 | 113.2 | 105.7 | 85 | 70 | |
Prawn | 4 | solid | 45 | 4 | 7 | 1,760 | 158.4 | 154.1 | 115 | 90 | |
Barnacles | 4 | 7/w | 45 | 4 | 7 | 1,760 | 168.3 | 158.2 | 115 | 90 | |
Shrimp | 2 | 7/w | 45 | 2 | 7 | 2,800 | 253.7 | 239.7 | 150 | 120 | |
Gammarus | 1/0 | 7/w | 60 | 1/0 | 7 | 4,460 | 411.7 | 386.0 | 205 | 160 | |
Leda | 1/0 | 19/w | 60 | 1/0 | 7 | 4,460 | 402.7 | 386.0 | 205 | 160 | |
Dungenese | 2/0 | 7/w | 60 | 2/0 | 7 | 5,390 | 506.8 | 476.3 | 235 | 185 | |
Cyclops | 2/0 | 19/w | 60 | 2/0 | 7 | 5,390 | 495.3 | 476.3 | 235 | 185 | |
Flustra | 3/0 | 19/w | 60 | 3/0 | 7 | 6,790 | 611.4 | 589.1 | 275 | 215 | |
Lepas | 4/0 | 19/w | 60 | 4/0 | 7 | 8,560 | 757.1 | 730.5 | 315 | 245 | |
6201 ALLOY REDUCED NEUTRAL-MESSENGER | |||||||||||
Artemia | 4 | solid | 45 | 6 | 7 | 1,110 | 141.4 | 137.1 | 115 | 90 | |
Crab | 4 | 7/w | 45 | 6 | 7 | 1,110 | 151.3 | 141.2 | 115 | 90 | |
Solaster | 2 | 7/w | 45 | 4 | 7 | 1,760 | 226.6 | 212.6 | 150 | 120 | |
Sandcrab | 1/0 | 7/w | 60 | 2 | 7 | 2,800 | 368.8 | 343.1 | 205 | 160 | |
Echinus | 1/0 | 19/w | 60 | 2 | 7 | 2,800 | 358.8 | 343.1 | 205 | 160 | |
Crayfish | 2/0 | 7/w | 60 | 1 | 7 | 3,530 | 452.6 | 422.5 | 235 | 185 | |
Sipho | 2/0 | 19/w | 60 | 1 | 7 | 3,530 | 441.0 | 422.5 | 235 | 185 | |
Fulgar | 3/0 | 19/w | 60 | 1/0 | 7 | 4,460 | 543.4 | 521.1 | 275 | 215 | |
Arca | 4/0 | 19/w | 60 | 2/0 | 7 | 5,390 | 671.2 | 644.6 | 315 | 245 | |
Code Name |
Phase Conductors | Bare Neutral | Weight Per 1000 ft.(lbs) |
Ampacity (Amps) | |||||||
Size AWG or MCM |
Stranding | Insulation thickness (mls) |
Size (AWG) |
*Stranding | Rated strength (lbs) |
XLP | Poly | XLP | Poly | ||
AAC NEUTRAL-MESSENGER | |||||||||||
Haiotis | 6 | solid | 45 | 6 | 7 | 563 | 102.5 | 98.8 | 85 | 70 | |
Patella | 6 | 7/w | 45 | 6 | 7 | 563 | 109.1 | 101.6 | 85 | 70 | |
Fusus | 4 | solid | 45 | 4 | 7 | 881 | 151.9 | 147.6 | 115 | 90 | |
Oyster | 4 | 7/w | 45 | 4 | 7 | 881 | 161.8 | 151.7 | 115 | 90 | |
Clam | 2 | 7/w | 45 | 2 | 7 | 1,350 | 243.2 | 229.2 | 150 | 120 | |
Murex | 1/0 | 7/w | 60 | 1/0 | 7 | 1,990 | 395.1 | 369.4 | 205 | 160 | |
Purpura | 1/0 | 19/w | 60 | 1/0 | 7 | 1,990 | 386.1 | 369.4 | 205 | 160 | |
Nassa | 2/0 | 7/w | 60 | 2/0 | 7 | 2,510 | 485.8 | 455.3 | 235 | 185 | |
Melita | 3/0 | 19/w | 60 | 3/0 | 19 | 3,310 | 585.2 | 562.9 | 275 | 215 | |
Portunus | 4/0 | 19/w | 60 | 4/0 | 19 | 4,020 | 723.9 | 697.3 | 315 | 245 | |
Nannynose | 336.4 | 19/w | 80 | 336.4 | 19 | 6,146 | 1160.4 | 1118.0 | 420 | 325 | |
WITH FULL SIZE ACSR MESSENGER | |||||||||||
Paludina | 6 | solid | 45 | 6 | 6/1 | 1,190 | 114 | 113 | 85 | 70 | |
Voluta | 6 | 7/w | 45 | 6 | 6/1 | 1,190 | 120 | 113 | 85 | 70 | |
Whelk | 4 | solid | 45 | 4 | 6/1 | 1,860 | 169 | 165 | 115 | 90 | |
Periwinkle | 4 | 7/w | 45 | 4 | 6/1 | 1,860 | 176 | 172 | 115 | 90 | |
Conch | 2 | 7/w | 45 | 2 | 6/1 | 2,850 | 267 | 261 | 150 | 120 | |
Neritina | 1/0 | 7/w | 60 | 1/0 | 6/1 | 4,380 | 530 | 419 | 205 | 160 | |
Cenia | 1/0 | 19/w | 60 | 1/0 | 6/1 | 4,380 | 426 | 416 | 205 | 160 | |
Runcina | 2/0 | 7/w | 60 | 2/0 | 6/1 | 5,310 | 530 | 519 | 235 | 185 | |
Triton | 2/0 | 19/w | 60 | 2/0 | 6/1 | 5,310 | 526 | 514 | 235 | 185 | |
Cherrystone | 3/0 | 7/w | 60 | 3/0 | 6/1 | 6,620 | 656 | 643 | 250 | 200 | |
Mursia | 3/0 | 19/w | 60 | 3/0 | 6/1 | 6,620 | 650 | 638 | 250 | 200 | |
Razor | 4/0 | 7/w | 60 | 4/0 | 6/1 | 8,350 | 814 | 799 | 315 | 245 | |
Zuzara | 4/0 | 19/w | 60 | 4/0 | 6/1 | 8,350 | 805 | 792 | 315 | 245 | |
Limpet | 336.4 | 19/w | 80 | 336.4 | 18/1 | 8,680 | 1209 | 1167 | 420 | 325 | |
Code Name |
Phase Conductors | Bare Neutral | Weight Per 1000 ft.(lbs) |
Ampacity (Amps) | |||||||
Size AWG or MCM | Stranding | Insulation thickness (mls) |
Size (AWG) |
Stranding | Rated strength (lbs) |
XLP | Poly | XLP | Poly | ||
WITH ACSR REDUCED SIZE MESSENGER | |||||||||||
Scallop | 4 | Solid | 45 | 6 | 6/1 | 1,190 | 148 | 144 | 115 | 90 | |
Strombus | 4 | 7/w | 45 | 6 | 6/1 | 1,190 | 158 | 148 | 115 | 90 | |
Cockle | 2 | 7/ w | 45 | 4 | 6/1 | 1,860 | 233 | 227 | 150 | 120 | |
Janthina | 1/0 | 7/ w | 60 | 2 | 6/1 | 2,850 | 376 | 365 | 205 | 160 | |
Ranella | 1/0 | 19/ w | 60 | 2 | 6/1 | 2,850 | 372 | 362 | 205 | 160 | |
Cavolinia | 2/0 | 7/ w | 60 | 1 | 6/1 | 3,550 | 462 | 451 | 235 | 185 | |
Clio | 2/0 | 19/ w | 60 | 1 | 6/1 | 3,550 | 458 | 446 | 235 | 185 | |
Sanddollar | 3/0 | 7/ w | 60 | 1/0 | 6/1 | 4,380 | 570 | 557 | 275 | 215 | |
Aega | 3/0 | 19/ w | 60 | 1/0 | 6/1 | 4,380 | 565 | 552 | 275 | 215 | |
Cuttlefish | 4/0 | 7/ w | 60 | 2/0 | 6/1 | 5,310 | 706 | 691 | 315 | 245 | |
Cerapus | 4/0 | 19/ w | 60 | 2/0 | 6/1 | 5,310 | 699 | 684 | 315 | 245 | |
Cowry | 336.4 | 19/ w | 80 | 4/0 | 6/1 | 8,350 | 1135 | 1093 | 420 | 325 |
3. Quadruplex Service Drop-Aluminum Conductor
Construction:
Conductors are concentrically stranded, compressed 1350-H19 aluminum, insulated with either polyethylene or XLP crosslinked polyethylene. Neutral messengers are concentrically stranded 6201, AAC, or ACSR, One conductor is manufactured with an extruded ridge for phase identification.
Standards: ASTM B-230, B-231, B-232, B-339 & ICEA S-76 -474
Code Name |
Phase Conductor | Bare Neutral Messenger | Weight Per 1000 ft(lbs) |
Rating(Amps) | ||||||
Size AWG |
Strand | Insulation thickness (mls) |
Size AWG |
Strand | Breaking strength (lbs) |
XLP | POLY | XLP | POLY | |
AAC NEUTRAL-MESSNGER | ||||||||||
Clydesdale | 4 | Solid | 45 | 4 | 7 | 881 | 208 | 201.8 | 100 | 80 |
Pinto | 4 | 7/w | 45 | 4 | 7 | 881 | 223 | 207.9 | 100 | 80 |
Mustang | 2 | 7/w | 45 | 2 | 7 | 1,350 | 333 | 312.6 | 135 | 105 |
Criollo | 1/0 | 19/w | 60 | 1/0 | 7 | 1,990 | 529 | 504.5 | 180 | 140 |
Percheron | 2/0 | 19/w | 60 | 2/0 | 7 | 2,510 | 649 | 620.5 | 205 | 160 |
Hanoverian | 3/0 | 19/w | 60 | 3/0 | 19 | 3,310 | 799 | 765.6 | 235 | 185 |
Oldenburg | 4/0 | 19/w | 60 | 4/0 | 19 | 4,020 | 986 | 946.7 | 275 | 210 |
Lippizaner | 336.4 | 19/w | 80 | 336.4 | 19 | 6,146 | 1,546 | 1,519.2 | 370 | 280 |
ACSR NEUTRAL-MESSNGER | ||||||||||
Morochuca | 6 | Solid | 45 | 6 | 6/1 | 1,190 | 152 | 147.4 | 75 | 60 |
Chola | 6 | 7/w | 45 | 6 | 6/1 | 1,190 | 162 | 151.7 | 75 | 60 |
Morgan | 4 | Solid | 45 | 4 | 6/1 | 1,860 | 226 | 220 | 100 | 80 |
Hackney | 4 | 7/w | 45 | 4 | 6/1 | 1,860 | 241 | 226.1 | 100 | 80 |
Palomino | 2 | 7/w | 45 | 2 | 6/1 | 2,850 | 362 | 342.6 | 135 | 105 |
Costena | 1/0 | 19/w | 60 | 1/0 | 6/1 | 4,380 | 575 | 550.6 | 180 | 140 |
Grullo | 2/0 | 19/w | 60 | 2/0 | 6/1 | 5,310 | 707 | 678.7 | 205 | 160 |
Suffolk | 3/0 | 19/w | 60 | 3/0 | 6/1 | 6,620 | 872 | 838.9 | 235 | 185 |
Appaloosa | 4/0 | 19/w | 60 | 4/0 | 6/1 | 8,350 | 1079 | 1039.2 | 275 | 210 |
Bronco | 336.4 | 19/w | 80 | 336.4 | 18/1 | 8,580 | 1613 | 1568.2 | 370 | 280 |
Gelding | 336.4 | 19/w | 80 | 4/0 | 6/1 | 8,350 | 1548 | 1494.3 | 370 | 280 |
Code Name |
Phase Conductor | Bare Neutral Messenger | Weight Per 1000 ft(lbs) |
Rating(Amps) | ||||||
Size AWG |
Strand | Insulation thickness (mls) |
Size AWG |
Strand | Breaking strength (lbs) |
XLP | POLY | XLP | POLY | |
6201 ALLOY NEUTRAL-MESSENGER | ||||||||||
Bay | 6 | Solid | 45 | 6 | 7 | 1,110 | 145 | 140.0 | 75 | 60 |
French Coach | 6 | 7/w | 45 | 6 | 7 | 1,110 | 155 | 144.3 | 75 | 60 |
German Coach | 4 | Solid | 45 | 4 | 7 | 1,760 | 214 | 208.3 | 100 | 80 |
Arabian | 4 | 7/w | 45 | 4 | 7 | 1,760 | 229 | 214.4 | 100 | 80 |
Belgian | 2 | 7/w | 45 | 2 | 7 | 2,800 | 344 | 323.1 | 135 | 105 |
Shetland | 1/0 | 19/w | 60 | 1/0 | 7 | 4,460 | 546 | 521.1 | 180 | 140 |
Thoroughbred | 2/0 | 19/w | 60 | 2/0 | 7 | 5,390 | 670 | 641.5 | 205 | 160 |
Trotter | 3/0 | 19/w | 60 | 3/0 | 7 | 6,790 | 825 | 791.8 | 235 | 185 |
Walking | 4/0 | 19/w | 60 | 4/0 | 7 | 8,560 | 1019 | 979.7 | 275 |
4. FAQ
(1).Are you a manufacturer or trading company?
We are a leading and profesional manufacturer of cable and wire, including: LV power cable, ABC, bare conductor, building wire, control cable and so on, with high quality.
(2). Is it sample available?
For stock product, of course, the sample is available for free. The sample will be released against the freight, and freight collect is also acceptable.
(3). Can we represent your SANWU CABLE to bid?
Highly welcome! We are looking for agency or partner in your local to promote our products, develop business, accordingly, we will provide nice condictions to make you get rich return.
(4). How about the package?
We can pack our products, by coil, carton, plastic bag, wooden drum/reel, steel-wooden drum/reel, steel drum/reel with strong protection to suit for the long-distance delivery.
5. Available Samples:
6. Factory Cable making machines:
7. Packing&Delivery:
We are China ACSR Abc Bundle Conductor AAC Aerial Bundle Conductor Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Tags: AAC Abc Bundle Conductor, AAC Aerial Bundle Conductor Cable, ACSR Abc Bundle Conductor, Aerial Bundled CableFAST AND RELIABLE SERVICE FOR YOUR PROJECT
Contact our trained experts today to find your perfect power solution.