0.6-1kv Low Voltage PVC/XLPE Insulated AAAC ACSR AAC Conductor Cable 3×50+35mm2

 China 0.6-1kv Low Voltage PVC/XLPE Insulated AAAC ACSR AAC Conductor Cable 3×50+35mm2 supplier

0.6-1kv Low Voltage PVC/XLPE Insulated AAAC ACSR AAC Conductor Cable 3×50+35mm2 image

Get a Quote Email to us

Brand Name :
Zhenglan Cable

Model Number :
0.6/1KV XLPE insulated service drop cable 3x25sqmm

Certification :
ISO 9001:2015,ISO 14001:2005; CCC

Place of Origin :
Henan, China

MOQ :
1000m

Price :
Negotiable

Payment Terms :
L/C, T/T, Western Union

Supply Ability :
15,000 KM/Year

Delivery Time :
15days

Packaging Details :
Wooden drum, iron wooden drum or as required

Insulation Material :
XLPE/PVC/PE

Conductor Material :
AAC/AAAC/ACSR

Application :
Overhead

Quality :
100% test

Standard :
GB/T 12527-2008, IEC60502-1

structure :
AL/XLPE/PVC/PE

Voltage :
0.6/1KV

Port :
Qingdao or Shanghai

0.6-1kv Low Voltage PVC/XLPE Insulated AAAC ACSR AAC Conductor Cable 3×50+35mm2 Service Drop Cable IEC60502-1 NFC33209

Application:

a. Duplex Service Drop
Application:To supply 120 volt aerial service for temporary service at construction sites,outdoor or street lighting . For service at 600 volts or lower at a conductor temperature of 75°C maximum.
b. Triplex Service Drop
Application: To supply power from the utility's lines to the consumer's weatherhead. For service at 600 volt or less (phase to phase) at a conductor temperature of 75°C maximum for polyethylene insulation 90°C maximum for crosslinked insulation.
c. Quadruplex Service Drop.
Used to supply 3 phase power, usually from a polemounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75°C for polyethylene insulation 90°C maximum for crosslinked polyethylene(XLPE) insulated conductors.

Conductor:

Conductors are concentrically stranded, compressed 1350- 19 Aluminum, Insulation with polyethylene or PVC or XLPE, Neutral messenger are concentrically stranded 6201 AAAC,AAC,or ACSR.

Insulation: PVC, XLPE, PE

Standards:
GB/T 12527-2008, IEC60502, IS:14255-1995
ANSI/ICEA S-76-474, NF C 33-209, AS3560-1-2000, IEC 60228, and ect.
Rated voltage: 0.6/1kV
We can also manufacture ABC cable according to customer's special requirements.

Number of Core:

1 core 2 core, 3 core, 4 core, 1+1 core, 2+1 core, 3+1 core, 1+1+1 core, 2+1+1core, 3+1+1core

Parameters:

SI. No. Description and Type of Cable Number of Wires Thickness of Approx overall Diameter Approx Weight of Cable Breaking Maximum D.C AC Current
XLPE Insulation Load of Resistance Rating
Phase Messenger Phase Messenger Messenger Ohms/Km Amps
mm mm mm Kg/KM KN (min) Phase Messenger In air at 40°C
With insulated messenger conductor
1 1 C x 16 mm2 + 25 mm2 (insulated) 7 7 1.2 1.2 20 165 7 1.91 1.38 72
2 3 C x 16 mm2 + 25 mm2 (insulated) 7 7 1.2 1.2 22 301 7 1.91 1.38 64
3 1 Cx25 mm2 + 25mm2(insulated) 7 7 1.2 1.2 22.4 195 7 1.2 1.38 99
4 3 C x 25 mm2 + 25 mm2 (insulated) 7 7 1.2 1.2 25 390 7 1.2 1.38 84
5 1 Cx35 mm2 + 25mm2(insulated) 7 7 1.2 1.2 27.3 227 7 0.868 1.38 120
6 3 C x 35 mm2 + 25 mm2 (insulated) 7 7 1.2 1.2 27.4 486 7 0.868 1.38 105
7 1 Cx35 mm2 + 35mm2(insulated) 7 7 1.2 1.2 28 259 10.1 0.868 0.986 120
8 3 C x 35 mm2 + 35 mm2 (insulated) 7 7 1.2 1.2 28.4 518 10.1 0.868 0.986 105
9 1 C x 50 mm2 + 35 mm2 (insulated) 7 7 1.5 1.2 29 317 10.1 0.641 0.986 150
10 3 C x 50 mm2 + 35 mm2 (insulated) 7 7 1.5 1.2 32.3 692 10.1 0.641 0.986 130
11 3Cx70 mm2 + 50 mm2 (insulated) 7 7 1.5 1.5 37.5 939 14 0.443 0.689 155
12 3 C x 70 mm2 + 70 mm2 (insulated) 7 7 1.5 1.5 39 1002 19.7 0.443 0.492 155
13 3 C x 95 mm2 + 70 mm2 (insulated) 19 7 1.5 1.5 42.7 1237 19.7 0.32 0.492 190
14 3 C x 120 mmz + 70 mm2 (insulated) 19 7 1.6 1.5 46 1482 19.7 0.253 0.492 220
15 3 C x 150 mm2 + 70 mm2 (insulated) 19 7 1.8 1.5 50 1791 19.7 0.206 0.492 250
With bare messenger conductor
1 1 C x 16 mm2 + 25 mm2 (bare) 7 7 1.2 / 18.5 137 7 1.91 1.38 72
2 3 C x 16 mm2 + 25 mm2 (bare) 7 7 1.2 / 19.3 272 7 1.91 1.38 64
3 1 C x 25 mm2 + 25 mm2 (bare) 7 7 1.2 / 19.5 167 7 1.2 1.38 99
4 3Cx25 mm2 + 25mm2(bare) 7 7 1.2 / 20.5 362 7 1.2 1.38 84
5 1 C x 35 mm2 + 25 mm2 (bare) 7 7 1.2 / 22 199 7 0.868 1.38 120
6 3 C x 35 mm2 + 25 mm2 (bare) 7 7 1.2 / 23.5 458 7 0.868 1.38 105
7 1 C x 35 mm2 + 35 mm2 (bare) 7 7 1.2 / 24.6 226 10.1 0.868 0.986 120
8 3Cx35 mm2 + 35 mm2 (bare) 7 7 1.2 / 25 485 10.1 0.868 0.986 105
9 1 C x 50 mm2 + 35 mm2 (bare) 7 7 1.5 / 26.6 284 10.1 0.641 0.986 150
10 3Cx50 mm2 + 35mm2(bare) 7 7 1.5 / 26.8 659 10.1 0.641 0.986 130
11 3 C x 70 mm2 + 50 mm2 (bare) 7 7 1.5 / 31.2 890 14 0.443 0.689 155
12 3Cx70 mm2 + 70mm2(bare) 7 7 1.5 / 34.4 946 19.7 0.443 0.492 155
13 3 C x 95 mm2 + 70 mm2 (bare) 19 7 1.5 / 36 1179 19.7 0.32 0.492 190
14 3 C x 120 mm2 + 70 mm2 (bare) 19 7 1.6 / 38 1425 19.7 0.253 0.492 220
15 3 C x 150 mm2 + 70 mm2 (bare) 19 7 1.8 / 40 1735 19.7__ 0.206 0.492 250 ―

Products images:

Why Choose Zhenglan Cable:

  • OEM/ODM services provided
  • Products comply with GB, IEC, BS, ASTM, DIN, VDE and JIS standards; Customer standard requirments Accepted
  • Certified to ISO 9001:2015, ISO 14001:2015 and OHSAS 18001:2007
  • Advanced test equipment and procedures, 100% inspection before factory
  • Enough stocks and the higest efficient shipping time guarranteed
  • Professional pre-sales and after-sales services provided
  • Strict quality control system, excellent quality with reasonable price.

FAQ
Q1: Is your company a factory or a trade company?
Factory, more than 20 years in China
Q2: How long can I expect to get the sample?
After you pay the freight charge and send us confirmed files, the samples will be ready for delivery in 3-7 days. The samples will be sent to you via express and arrive in 3~7 days. You can use your own express account or prepay us if you do not have an account.
Q3: What are your payment terms?
We normally accept T/T 30% deposit, 70% balance before delivery as the main payment terms, and other payment can also be negotiated. Trade assurance on Alibaba is also available.
Q4: What’s the delivery time?
Sample order needs 3~5 days. Formal order depends on the quantity. Usually it needs 7-30 days after get your payment.
Q5: What is your MOQ?
Generally it is 5000m.

We are China 0.6-1kv Low Voltage PVC/XLPE Insulated AAAC ACSR AAC Conductor Cable 3×50+35mm2 manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION