500 KV XLPE Insulated Power Cable
500 KV XLPE Insulated Power Cable image
Brand Name :
huiyou
Certification :
ISO9001,ISO14001,ISO18001, CE
Place of Origin :
china
MOQ :
100M
Payment Terms :
L/C, T/T
Delivery Time :
10000.00KM
Packaging Details :
wooden drum, steel drum, soft pack
500 KV XLPE Insulated Power Cable
Standard
We produced according to National Standard of GB/T 22078.2-2008 of the People’s Republic of China.
Range of application
It is suitable for single-core cable’s installation and operation under normal conditions of rated voltage 290/500 KV, but it is not suitable for cable in special use, such as submarine cable.
Characteristics of cable
●Rated voltage of cable is U0=290 KV,U=500 KV,Um=550 KV.
●The allowable maximum temperature of cable conductor is 90℃ when it runs in normal, and 250℃ when it short circuited (Longest time is 5 s).
●The allowable minimum bending radius is 20 times of cable outside diameter when installed. After installation , the minimum bending radius is recommended for 15 times of cable outside diameter.
Service environment( Place )
●Lead sheath cable, is suitable for environment with more serious corrosion but no much nitric acid, acetic acid and organic matter ( Such as mud, coal and strong alkaline corrosion matter with technical force, stress and vibration etc.)
●Aluminium sheath cable, is suitable for environment with minor corrosion and required to bear a certain mechanical force ( For example, connected with transformer directly and laying at bridge opening or in shaft etc.)
●Metal plastic compound sheath cable is suitable for general damp and warm place , no corrosion or light corrosion and no direct contact with water and bear not so much technical force , pulling force , stress and vibration.
●PVC outer sheath cable is mainly used in cable line with general fire-proof requirement and insulation requirement for outer sheath.
●PE outer sheath cable is mainly suitable for directly buried laying cable line with higher requirement on outer sheath insulation, low temperature environment under 20℃, or soaked place by chemical liquid and low toxicity requirement when cable burns, when PE outer sheath is used in tunnel or shaft , fire-control and flame-retardant measures should be adopted if necessary.
Model and Name of product
Model | Name of cable |
Copper core | |
YJLW02 | XLPE insulated corrugated aluminium sheath or welding aluminium sheath PVC sheath power cable |
YJLW03 | XLPE insulated corrugated aluminium sheath or welding aluminium sheath PE sheath power cable |
YJLW02-Z | XLPE insulated corrugated aluminium sheath or welding aluminium sheath longitudinally water blocking PVC sheath power cable |
YJLW03-Z | XLPE insulated corrugated aluminium sheath or welding aluminium sheath longitudinally water blocking PE sheath power cable |
YJQ02 | XLPE insulated lead sheath PVC sheath power cable |
YJQ03 | XLPE insulated lead sheath PVC sheath power cable |
YJQ02-Z | XLPE insulated lead sheath PVC sheath longitudinally water blocking power cable |
YJQ03-Z | XLPE lead insulated lead sheath PV sheath longitudinally water blocking power cable |
Conductor structure , specifications , insulation thickness
Specifications Conductorcross-section (mm2) | structure | Minimum number of single wire in conductor | Maximum of conductordirect-current resistance(Ω/km) | Insulation nominal thickness |
800 | Round conductor/Segmental conductor | 53 | 0.0221 | 34 |
1000 | Segmental conductor | 170 | 0.0176 | 33 |
1200 | Segmental conductor | 170 | 0.0151 | 33 |
1400 | Segmental conductor | 170 | 0.0129 | 32 |
1600 | Segmental conductor | 170 | 0.0113 | 32 |
1800 | Segmental conductor | 265 | 0.0101 | 31 |
2000 | Segmental conductor | 265 | 0.0090 | 31 |
2200 | Segmental conductor | 265 | 0.0083 | 31 |
2500 | Segmental conductor | 265 | 0.0073 | 31 |
Representation method of product
●For example
A. Single-core copper conductor with rated voltage of 290/500 KV, nominal sectional area of 1200 mm2, so XLPE insulated corrugated aluminium sheath PVC sheath power cable will be represented as : YJLW02-290/500 KV – 1×1200 GB/T 22078.2-2008.
B. Single-core copper conductor with rated voltage of 290/500 KV , nominal sectional area of 2500 mm2, so XLPE insulated corrugated lead sheath PVC sheath longitudinally water blocking power cable will be represented as : YJQ03-Z-290/500 KV- 1×2500 GB/T22078.2-2008.
We are China 500 KV XLPE Insulated Power Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.