4 Core FRC Flame Retardant Cable 600V / 1000V With Fire Resistant Screen
4 Core FRC Flame Retardant Cable 600V / 1000V With Fire Resistant Screen image
Brand Name :
SHANCABLE
Model Number :
NH-YJV
Certification :
CE/KEMA/ISO/PCCC
Place of Origin :
SHANGHAI,CHINA
MOQ :
200m
Price :
USD0.03-5.0
Supply Ability :
10KM per Week
Delivery Time :
As per requirement
Packaging Details :
100m/roll or customized
Function :
Fire Resistant
Size :
1.5mm2 -800mm2
Rated Voltage :
600/1000kV
Insulation :
PVC/XLPE
Sample :
Optional
Number of cores :
1,2,3,4,5
Application :
Buidings
4 Core FRC Flame Retardant Cable 600V / 1000V With Fire Resistant Screen
Cable Structure
Conductor : Class 1,2,5 Flexible Copper Conductor
Screen: Mica tape
Insulation: PVC or LSZH PO
Sheath:PVC: (Optional)
Rated Voltage : 450/750V
Fire Resistant Cables
225V SR Insulated & LSZH Sheathed Fire Alarm Cables
300V Mica+LSZH Insulated & LSZH Sheathed Fire Alarm Cables
225 SR Insulated & LSZH Sheathed Fire Alarm Cables BMK*
300/500V SR Insulated & LSZH Sheathed Fire Alarm Cables
300/500V Mica+XLPE Insulated & LSZH Sheathed Fire Alarm Cables
Rated Voltage: 0.6/1KV
Range of Nominal cross section: 1 core: 1.5 mm2 ~ 300 mm2 Multi core: 0.75 mm2 ~ 35 mm2
Application:
These cables are installed to supply power to building essential services including fire alarms,
sprinkler control system, emergency and evacuation lighting and smoke control systems,
such as high rise buildings and apartments, airports, shopping centres, cinemas and road and rail tunnels
Constructions
Conductor: Class 1/2 Plain annealed copper wires, solid or stranded, with mica tape wound
Insulation: XLPE or LSZH compound
Sheath: LSZH compound
Core color: red, black, blue, white for active core, green/yellow for earth core, orange or red or black for sheath
Max. Operating Temperature :100 meters per roll or wooden drum or as per requirement
Production Capacity : 20 kilometer/ day
MOQ : 5000 meters for small size, 1000 meters for big size
Certificates
CE, RoHS, CCC, KEMA and more others at request
Nom. Cross-section of conductor | Insulation Thickness | Sheath | Approx. | Approx | Max. D.C. Resistance of Conductor (20°C) | Test Voltage | Current Rating | |
mm2 | mm | Thickness | O.D. | Weight | Ω/km | A.C | ||
mm | mm | kg/km | kV/5min | In air(A) | In soil(A) | |||
1×1.5 | 0.7 | 1.8 | 7.7 | 81 | 12.1 | 3.5 | 22 | 33 |
4×1.5 | 0.7 | 1.8 | 14.4 | 241 | 12.1 | 3.5 | 20 | 27 |
4×2.5 | 0.7 | 1.8 | 15.4 | 295 | 7.41 | 3.5 | 26 | 35 |
4×4 | 0.7 | 1.8 | 16.5 | 369 | 4.61 | 3.5 | 34 | 45 |
4×6 | 0.7 | 1.8 | 17.8 | 463 | 3.08 | 3.5 | 43 | 57 |
4×10 | 0.7 | 1.8 | 20.9 | 667 | 1.83 | 3.5 | 60 | 77 |
4×16 | 0.7 | 1.8 | 23.4 | 930 | 1.15 | 3.5 | 83 | 105 |
4×25 | 0.9 | 1.8 | 27.1 | 1351 | 0.727 | 3.5 | 105 | 125 |
4×35 | 0.9 | 1.8 | 29.5 | 1772 | 0.524 | 3.5 | 125 | 155 |
4×50 | 1 | 1.9 | 38.4 | 2380 | 0.387 | 3.5 | 160 | 185 |
4×70 | 1.1 | 2 | 43.2 | 3302 | 0.268 | 3.5 | 200 | 225 |
4×95 | 1.1 | 2.2 | 47.3 | 4330 | 0.193 | 3.5 | 245 | 270 |
4×120 | 1.2 | 2.3 | 52.5 | 5374 | 0.153 | 3.5 | 285 | 310 |
4×150 | 1.4 | 2.5 | 58.3 | 6655 | 0.124 | 3.5 | 325 | 345 |
4×185 | 1.6 | 2.7 | 64.7 | 8246 | 0.0991 | 3.5 | 375 | 390 |
4×240 | 1.7 | 2.9 | 73.1 | 10569 | 0.0754 | 3.5 | 440 | 450 |
4×2.5+1×1.5 | 0.7 | 1.8 | 16.5 | 313 | 7.41 | 26 | 35 | |
4×4+1×2.5 | 0.7 | 1.8 | 17.7 | 424 | 4.61 | 34 | 45 | |
4×6+1×4 | 0.7 | 1.8 | 19.1 | 535 | 3.08 | 43 | 57 | |
4×10+1×6 | 0.7 | 1.8 | 22.1 | 760 | 1.83 | 60 | 77 | |
4×16+1×10 | 0.7 | 1.8 | 25.1 | 1071 | 1.15 | 83 | 105 | |
4×25+1×16 | 0.7 | 1.8 | 29 | 1556 | 0.727 | 105 | 125 | |
4×35+1×16 | 0.9 | 1.9 | 31.4 | 1976 | 0.524 | 125 | 155 | |
4×50+1×25 | 1 | 2.1 | 36 | 2689 | 0.387 | 160 | 185 | |
4×70+1×35 | 1.1 | 2.2 | 41.1 | 3719 | 0.268 | 200 | 225 | |
4×95+1×50 | 1.1 | 2.4 | 46.3 | 4903 | 0.193 | 245 | 270 | |
4×120+1×70 | 1.2 | 2.5 | 51 | 6165 | 0.153 | 285 | 310 | |
4×150+1×70 | 1.4 | 2.7 | 55.8 | 7431 | 0.124 | 325 | 345 | |
4×185+1×95 | 1.6 | 2.9 | 62.1 | 9192 | 0.0991 | 375 | 390 | |
4×240+1×120 | 1.7 | 3.1 | 68.8 | 11860 | 0.0754 | 440 | 450 |
Operating characteristics
1,Long-term allowable operating temperature of cable conductor ≤70°C
2,Highest working temperature of cable in case of short circuit (the longest lasting time is not over 5s):≤300mm2 cable conductor ≤160°C, ≥300 mm2 cable conductor≤ 140°C.
3,The laying temperature should over 0℃,Permissible bending radius of cable:for single core unarmored cable, should be no less than 20 times of it’s outer diameter ; for multi-core unarmored cable, should be no less than 15 times of it’s outer diameter
4,With flame-retardant property,ZA,ZB,ZC,ZD are 4 types
5,The product is applicable for AC 50 Hz transmission and distribution lines with rated voltage of 0.6/1KV
Q: Are you trading company or manufacturer ?
A: We are factory.
Q: How long is your delivery time?
A: Generally 5-15 days , according to the quantity.
Q: Do you provide samples ? is it free or extra ?
A: Yes, we could offer the sample for free charge but do not pay the cost of freight.
Q: What is your terms of payment ?
A: Usually 30% T/T deposit , balance before shippment.
We are China 4 Core FRC Flame Retardant Cable 600V / 1000V With Fire Resistant Screen manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Tags: fire proof cable, Fire Resistant Cable, flame resistant cable