4 Core Copper Cross Linked Polyethylene Cable For Underground / Power Station
4 Core Copper Cross Linked Polyethylene Cable For Underground / Power Station image
Brand Name :
Huanghe
Model Number :
XLPE Insulated Copper Cable
Certification :
IOS OHSAS CCC IEC
Place of Origin :
China
MOQ :
200
Payment Terms :
TT/Western Union /LC
Supply Ability :
50000meters per week
Delivery Time :
5-8days
Packaging Details :
wooden drum
Conductor Core :
Annealed Copper
Insulation :
Cross Linked Polyethylene (XLPE)
Outer Sheath :
Polyvinyl Chloride (PVC) or Polyethylene (PE)
Armoured Type :
DSTA/SWA/AWA Armored or Unarmored
Rated Voltage :
0.6/1KV
Cross Section Area :
0.75mm2-1000mm2
Number of Cores :
1 core to 5 cores
Standards :
IEC60502, BS IEC ASTM DIN, GB/T12706, VDE, UL
Colour :
Black or Customized
Application :
Construction, Industrial, Underground, Power Station
Feature :
Abrasion-resistant
Fire Performance of Cable Sheaths :
Cables can be supplied with special flame retardant PVC outer sheath to comply with the flame test requirements.
Packing :
Drum, Optional
4 Core Copper Cross Linked Polyethylene Cable For Underground / Power Station
XLPE Insulated Copper Cable Rated Voltage:
0.6/1KV
XLPE Insulated Copper Cable Number of cores:
1 core, 2 core, 3 core, 3+1 core, 3+2 core, 4 core, 4+1 core, 5 core
XLPE Insulated Copper Cable Application:
XLPE insulated copper cables are used for electricity supply in low voltage installation system. They are suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants. The sta/swa/awa armoured copper cables could bear external force.
Low Voltage Copper Cable Construction:
XLPE Insulated Copper Cable Operating Performance:
1). Rated power frequency voltage Uo/U: 0.6/1KV.
2). Max. Permissible continuous operating temperature of conductor: 90℃
3). Max. Short-circuit temperature of the conductor shall not exceed: (5S maximum duration) 250℃
4). The ambient temperature under installation should not below 0℃
5). The bending radius of a cable should not be less than 15 times of the cable diameter.
6). The test voltage (A.C.): 3.5kV/5min.
7). The flame-retardant properties of cable comply with grade A, B, C of GB/T19666-2005 or IEC60332.
XLPE Insulated Cable Types:
0.6/1kV XLPE Insulated Electric Cable | |||
XLPE Cable Types | Description | Cores | Nomi Section Area (mm2) |
Cu/XLPE/PVC | copper core, xlpe insulated, pvc sheathed, electric cable |
1 core 2 core 3 core 4 core 5 core 3+1 core 3+2 core 4+1 core |
1.5, 2.5, 4, 6, 10, 25, 35, 50, 70, 95, 120, 150, 185, 240, 300, 400, 500, 630, 800, 1000 |
Al/XLPE/ PVC | aluminum core, xlpe insulated, pvc sheathed, electric cable | ||
Cu/XLPE/STA/PVC | copper core, xlpe insulated, steel tape armoured, pvc sheathed, electric cable | ||
Al/XLPE/STA/PVC | aluminum core, xlpe insulated, steel tape armoured, pvc sheathed, electric cable | ||
Cu/XLPE/SWA/PVC | copper core, xlpe insulated, steel wire armoured, pvc sheathed, electric cable | ||
Al/XLPE/SWA/PVC | aluminum core, xlpe insulated, steel wire armoured, pvc sheathed, electric cable |
Medium Voltage XLPE Insulated Electric Cable | |||
XLPE Cable Types | Description | Cores | Nomi Section Area (mm2) |
Cu/XLPE/PVC | copper core, xlpe insulated, pvc sheathed, electric cable |
1 core 3 core |
25, 35, 50, 70, 95, 120, 150, 185, 240, 300, 400, 500, 630, 800, 1000 |
Al/XLPE/ PVC | aluminum core, xlpe insulated, pvc sheathed, electric cable | ||
Cu/XLPE/STA/PVC | copper core, xlpe insulated, steel tape armoured, pvc sheathed, electric cable | ||
Al/XLPE/STA/PVC | aluminum core, xlpe insulated, steel tape armoured, pvc sheathed, electric cable | ||
Cu/XLPE/SWA/PVC | copper core, xlpe insulated, steel wire armoured, pvc sheathed, electric cable | ||
Al/XLPE/SWA/PVC | aluminum core, xlpe insulated, steel wire armoured, pvc sheathed, electric cable |
1KV 4 Core XLPE Insulated Cable (Uarmoured) Technical Data:
No.cores x cross-sec. |
Insulation thickness |
Sheath thickness Nominal value |
Outer Ø approx. |
weight approx. |
Current ratings in air 30℃ | Current ratings buried 20℃ | maximum DC resistance at 20℃ |
mm2 | mm | mm | mm | kg/km | A | A | Ω/km |
4×4 | 0.7 | 1.8 | 13.0 | 283 | 38 | 50 | 4.61 |
4×6 | 0.7 | 1.8 | 14.2 | 376 | 49 | 62 | 3.08 |
4×10 | 0.7 | 1.8 | 16.7 | 567 | 67 | 84 | 1.83 |
4×16 | 0.7 | 1.8 | 19.1 | 829 | 88 | 109 | 1.15 |
4×25 | 0.9 | 1.8 | 23.2 | 1249 | 119 | 142 | 0.73 |
4×35 | 0.9 | 1.8 | 25.2 | 1689 | 146 | 170 | 0.52 |
4×50 | 1.0 | 1.9 | 25.5 | 2146 | 173 | 201 | 0.39 |
4×70 | 1.1 | 2.0 | 28.9 | 2944 | 218 | 245 | 0.27 |
4×95 | 1.1 | 2.1 | 32.5 | 3903 | 271 | 294 | 0.19 |
4×120 | 1.2 | 2.3 | 35.9 | 4967 | 315 | 333 | 0.15 |
4×150 | 1.4 | 2.4 | 40.2 | 6133 | 366 | 374 | 0.12 |
4×185 | 1.6 | 2.6 | 44.4 | 7600 | 422 | 421 | 0.10 |
4×240 | 1.7 | 2.8 | 49.4 | 9746 | 508 | 489 | 0.08 |
4×300 | 1.8 | 3.0 | 56.0 | 12271 | 592 | 555 | 0.06 |
We are China 4 Core Copper Cross Linked Polyethylene Cable For Underground / Power Station manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Tags: cross linked polyethylene wire, xlpe copper cable, xlpe insulated wire