3 Phase Conductor Aerial Bundled Cable 5 Core Excellent Corrosion Resistant

 China 3 Phase Conductor Aerial Bundled Cable 5 Core Excellent Corrosion Resistant supplier

3 Phase Conductor Aerial Bundled Cable 5 Core Excellent Corrosion Resistant image

Get a Quote Email to us

Brand Name :
SHANCABLE

Model Number :
ABC-AL/XLPE/1KV-5 Cores

Certification :
IEC 60502

Place of Origin :
Shanghai, China

MOQ :
0.5km

Price :
0.10-25.99USD/m

Payment Terms :
L/C, D/A, D/P, T/T, Western Union, MoneyGram

Supply Ability :
1000km per Month

Delivery Time :
10 Days or More

Packaging Details :
Wooden Drum or Steel Drum

Phase Conductor :
Aluminium

Neutral Conductor :
Aluminium Alloy

Street Lighting :
Aluminium

Cores Nos :
5

Insulation :
XLPE

Rated Voltage :
0.6/1 KV

3 Phase Conductor Aerial Bundled Cable 5 Core Excellent Corrosion Resistant

Description

The aerial Bundled cables designed for overhead distribution lines have an insulated neutral messenger made of AAAC, which the insulated aluminium phase conductor are helically wound over it. Cables are rated at 0.6/1(1.2)kV and conform to IEC60502.

Construction

  1. Conductor:

a) Phase – The phase conductor shall be of H68 Condition aluminium conductor and compacted circular stranded.

b) Neutral or messenger – The Neutral or messenger conductor shall be of aluminium alloy conductor and compacted circular stranded c)Street Lighting- The street lighting conductors shall be of H68 condition aluminium conductor and compacted circular stranded..

  1. Insulation:

The phase, neutral conductors shall be extruded with XLPE as insulation.

Schedule of technical particulars

Phase conductor
Nominal cross-sectional area mm² 25 35 50 70 95 120 150 185
Number of cores 3 3 3 3 3 3 3 3
Minimum number of wires 6 6 6 12 15 15 30 30
Nominal insulation thickness mm 1.2 1.2 1.4 1.4 1.6 1.6 1.8 2.0
Diameter of insulated core mm 8.5 9.5 11.2 13.0 15.1 16.6 18.4 20.6
Max. DC resistance at 20℃ ohm/km 1.20 0.868 0.641 0.443 0.320 0.253 0.206 0.164
Current rating at still wind, ambient A 84 104 129 167 209 246 283 332
temperature=30℃
Conductor temperature=75℃
Messenger conductor
Nominal cross-sectional area mm² 25 25 35 50 70 70 95 120
Minimum number of wires 6 6 6 6 12 12 15 15
Nominal insulation thickness mm 1.2 1.2 1.2 1.4 1.4 1.4 1.6 1.6
Diameter of insulated core mm 8.5 8.5 9.5 11.2 13.1 13.1 15.1 16.6
Max. DC resistance at 20℃ ohm/km 1.312 1.312 0.943 0.693 0.469 0.469 0.349 0.273
Calculated breaking load kN 6.4 6.4 8.9 12.1 18.0 18.0 24.2 30.8
Street lighting conductor
Nominal cross-sectional area mm² 25 25 35 50 70 70 95 120
Minimum number of wires 6 6 6 6 12 12 15 15
Nominal insulation thickness mm 1.2 1.2 1.2 1.4 1.4 1.4 1.6 1.6
Diameter of insulated core mm 8.5 8.5 9.5 11.2 13.1 13.1 15.1 16.6
Max. DC resistance at 20℃ ohm/km 1.312 1.312 0.943 0.693 0.469 0.469 0.349 0.273
Completed cable
Approx. overall diameter mm 23.2 25.6 30.0 34.9 40.6 44.1 49.2 54.9
Approx. weight of cable kg/km 470 560 740 980 1330 1580 1940 2410
Packing length m/drum 1000 1000 1000 1000 500 500 500 500

STANDARD NF C 33-209

NFA 2X

Phases Neutral/Messenger
Distribution Lines Pub. Lighting
Cable Type Number of Number of Avarage Resistance Number of Conductance Avarage Rated Resistance
core wire diameter at 20℃ core at 30℃ diameter Strength at 20℃
mm² mm² PCS mm ohm/km mm² A mm kN ohm/km
2×16 2×16 7 4.6 1.91
2×35 2×35 7 5.9 1.20
2×35 2×35 7 6.9 0.868
2×50 2×50 7 8.1 0.641
4×16 4×16 7 4.6 1.91
4×25 4×25 7 5.9 1.20
4×35 4×35 7 6.9 0.868
3×25+54.6 3×25 7 5.9 1.20 9.6 16.0 0.63
3×25+1×16+54.6 3×25 7 5.9 1.20 1×16 60 9.6 16.0 0.63
3×25+2×16+54.6 3×25 7 5.9 1.20 2×16 9.6 16.0 0.63
3×35+54.6 3×35 7 6.9 0.868 9.6 16.0 0.63
3×35+1×16+54.6 3×35 7 6.9 0.868 1×16 60 9.6 16.0 0.63
3×35+2×16+54.6 3×35 7 6.9 0.868 2×16 9.6 16.0 0.63
3×50+54.6 3×50 7 8.1 0.641 9.6 16.0 0.63
3×50+1×16+54.6 3×50 7 8.1 0.641 1×16 60 9.6 16.0 0.63
3×50+2×16+54.6 3×50 7 8.1 0.641 2×16 9.6 16.0 0.63
3×70+54.6 3×70 12 9.7 0.443 9.6 16.0 0.63
3×70+1×16+54.6 3×70 12 9.7 0.443 1×16 60 9.6 16.0 0.63
3×70+2×16+54.6 3×70 12 9.7 0.443 2×16 9.6 16.0 0.63
3×70+1×25+54.6 3×70 12 9.7 0.443 1×25 9.6 16.0 0.63
3×70+2×25+54.6 3×70 12 9.7 0.443 2×25 9.6 16.0 0.50
3×70+70 3×70 12 9.7 0.443 10.2 20.6 0.50
3×70+1×16+70 3×70 12 9.7 0.443 1×16 60 10.2 20.6 0.50
3×70+2×16+70 3×70 12 9.7 0.443 2×16 10.2 20.6 0.50
3×95+70 3×95 12 11.5 0.320 10.2 20.6 0.50
3×95+1×16+70 3×95 12 11.5 0.320 1×16 60 10.2 20.6 0.50
3×95+2×16+70 3×95 12 11.5 0.320 2×16 10.2 20.6 0.50
3×120+70 3×120 12 12.8 0.253 10.2 20.6 0.50
3×120+1×16+70 3×120 19 12.8 0.253 1×16 10.2 20.6 0.50
3×120+2×16+70 3×120 19 12.8 0.253 2×16 60 10.2 20.6 0.50
3×150+70 3×150 19 14.5 0.206 10.2 20.6 0.50
3×150+1×16+70 3×150 19 14.5 0.206 1×16 10.2 20.6 0.50
3×150+2×16+70 3×150 19 14.5 0.206 2×16 60 10.2 20.6 0.50
3×120+95 3×120 19 12.8 0.253 12.9 27.9 0.343
3×120+1×16+95 3×120 19 12.8 0.253 1×16 12.9 27.9 0.343
3×120+2×16+95 3×120 19 12.8 0.253 2×16 60 12.9 27.9 0.343
3×150+95 3×150 19 14.5 0.206 12.9 27.9 0.343
3×150+1×16+95 3×150 19 14.5 0.206 1×16 12.9 27.9 0.343
3×150+2×16+95 3×150 19 14.5 0.206 2×16 60 12.9 27.9 0.343

Aerial Bundled Cables with Street Lighting Conductor

3 Phase conductors + 1 Messenger conductor + 1 Street lighting conductor

We are China 3 Phase Conductor Aerial Bundled Cable 5 Core Excellent Corrosion Resistant manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Tags: , ,