2kV Up To 25kV Special Cables Mining Power Cable EPR Insulation Braided Metallic Shield
2kV Up To 25kV Special Cables Mining Power Cable EPR Insulation Braided Metallic Shield image
Brand Name :
CN CABLE
Model Number :
Power cable
Certification :
IEC
Place of Origin :
Henan
MOQ :
1000meters
Payment Terms :
L/C, T/T
Delivery Time :
20days after payments
Packaging Details :
drum
Conductor :
Extra- flexible copper conductor, according ASTM B3
Conductor Shield :
Semi-conducting tapes shield applied helically over the conductor
Insulation :
100% insulation level oil, ozone and water resistant Ethylene propylene rubber (EPR) 90°C normal temperature operation, 130°C emergency overload condition, 250°C short circuit condition
Insulation shield :
Up to 2kV polyester tape applied over the insulation; over 2kV semi-conducting tapes shield applied over the insulation
Metallic shield :
Tinned copper braid (60% minimum coverage) over each conductor
Phases identification :
By colored fibers Black, White and Red
Ground wires :
Two bare, rope-lay flexible stranded, copper conductors
Ground check :
One yellow insulated, rope-lay flexible stranded, copper conductor
Core assembly :
Three phase conductors, two bare ground and one ground check conductors are cabled together with a left hand lay, plus a binder tape applied over the assembly
Reinforcement :
An open reinforcement is applied over the core for mechanical strength
Jacket :
Extra heavy duty elastomer jacket highly resistant to cutting, tear, sunlight, ozone and flame. It has an excellent resistance to heat, moisture, water, oil and most chemicals commonly present at mining field operations. The standard jacket is black and me
2 kV Up to 25 kV Mining Power Cable, EPR Insulation, Braided Metallic Shield, Thermosetting Rubber Extra Heavy Duty Jacket
Application
For heavy duty medium voltage service as power supply for mining equipment where maximum safety is required. Commonly used to feed heavy mobile mining equipment such as shovels, dredges, drilling rigs, other off track equipment. Also suitable for medium voltage distribution as a flexible power supply cable in extra heavy duty operations. SHD-GC cables are designated to operate on three phases AC circuit, where grounding conductors and ground check conductor are required. Ground check control cable allows monitory all the time ground circuit conductors to give maximum safety level.
Detail Description & Construction
Conductor | Extra- flexible copper conductor, according ASTM B3 |
Conductor Shield | Semi-conducting tapes shield applied helically over the conductor |
Insulation | 100% insulation level oil, ozone and water resistant Ethylene propylene rubber (EPR) 90°C normal temperature operation, 130°C emergency overload condition, 250°C short circuit condition |
Insulation shield | Up to 2kV polyester tape applied over the insulation; over 2kV semi-conducting tapes shield applied over the insulation |
Metallic shield | Tinned copper braid (60% minimum coverage) over each conductor |
Phases identification | By colored fibers Black, White and Red |
Ground wires | Two bare, rope-lay flexible stranded, copper conductors |
Ground check | One yellow insulated, rope-lay flexible stranded, copper conductor |
Core assembly | Three phase conductors, two bare ground and one ground check conductors are cabled together with a left hand lay, plus a binder tape applied over the assembly |
Reinforcement | An open reinforcement is applied over the core for mechanical strength |
Jacket | Extra heavy duty elastomer jacket highly resistant to cutting, tear, sunlight, ozone and flame. It has an excellent resistance to heat, moisture, water, oil and most chemicals commonly present at mining field operations. The standard jacket is black and meets or exceeds all the requirements of ICEA S75-381. Alternate jacket colors are available as request |
Packaging
Non-returnable wooden drums.
Options
• Thermoplastic Polyurethane (TPU)
• Jacket (MSHA approved)
• Jacket colors
• Put-up length (300 m)
Standards/Testing
SHD-GC meets or exceeds the requirements of ICEA S-75-381, ICEA S-68-516 and is MSHA approved using TPU jacket.
Marking
SHD-GC.
Installation
SHD-GC can be used in outdoors locations under very severe environmental conditions such as the one commonly present at mining places. Conductor design and raw materials used, allows the cable to be installed directly on rough mining fields, not requiring any previous preparation.
CABLE TYPE SHD-GC 2 kv | |||||||||||
Conductor Size |
Nominal Area |
No. Threads Minimum |
Conductor Diameter |
Insulation Thickness |
Grounding Conductor Size |
Control Conductor Size |
Jacket Thickness |
OD Nominal |
Approx. Total Weight |
Min. Bending Radius |
Ampacity |
AWG / MCM | mm2 | mm | mm | AWG | AWG | mm | mm | kg / km | mm | A | |
6 | 13.3 | 49 | 5.49 | 1.78 | 10 | 8 | 3.94 | 32.8 | 1,799 | 197 | 93 |
4 | 21.2 | 49 | 6.82 | 1.78 | 8 | 8 | 3.94 | 35.5 | 2,220 | 214 | 122 |
3 | 26.7 | 49 | 7.77 | 1.78 | 7 | 8 | 4.32 | 38.4 | 2,633 | 230 | 140 |
2 | 33.6 | 133 | 8.68 | 1.78 | 6 | 8 | 4.32 | 40.4 | 2,968 | 242 | 159 |
1 | 42.4 | 133 | 9.83 | 2.03 | 5 | 8 | 4.83 | 44.7 | 3,640 | 268 | 184 |
1/0 | 53.5 | 133 | 10.98 | 2.03 | 4 | 8 | 4.83 | 47.2 | 4,189 | 283 | 211 |
2/0 | 67.4 | 133 | 12.68 | 2.03 | 3 | 8 | 5.21 | 50.8 | 4,694 | 305 | 243 |
3/0 | 85 | 259 | 13.89 | 2.03 | 2 | 8 | 5.21 | 54.1 | 5,817 | 325 | 279 |
4/0 | 107 | 259 | 15.79 | 2.03 | 1 | 8 | 5.59 | 58.7 | 6,983 | 352 | 321 |
250 | 127 | 259 | 16.84 | 2.41 | 1/0 | 8 | 5.59 | 63.8 | 8,280 | 383 | 355 |
350 | 177 | 259 | 20.24 | 2.41 | 2/0 | 8 | 5.97 | 71.5 | 10,689 | 429 | 435 |
500 | 253 | 259 | 23.92 | 2.41 | 4/0 | 8 | 6.73 | 81.0 | 14,483 | 485 | 536 |
CABLE TYPE SHD-GC 5 kV | |||||||||||
Conductor Size |
Nominal Area |
No. Threads Minimum |
Conductor Diameter |
Insulation Thickness |
Grounding Conductor Size |
Control Conductor Size |
Jacket Thickness |
OD Nominal |
Approx. Total Weight |
Min. Bending Radius |
Ampacity |
AWG / MCM | mm2 | mm | mm | AWG | AWG | mm | mm | kg / km | mm | A | |
6 | 13.3 | 49 | 5.49 | 2.79 | 10 | 8 | 4.70 | 39.6 | 2,327 | 238 | 93 |
4 | 21.2 | 49 | 6.82 | 2.79 | 8 | 8 | 4.70 | 42.7 | 2,815 | 256 | 122 |
3 | 26.7 | 49 | 7.77 | 2.79 | 7 | 8 | 5.21 | 45.2 | 3,237 | 271 | 140 |
2 | 33.6 | 133 | 8.68 | 2.79 | 6 | 8 | 5.21 | 47.5 | 3,631 | 285 | 159 |
1 | 42.4 | 133 | 9.83 | 2.79 | 5 | 8 | 5.21 | 49.5 | 4,101 | 297 | 184 |
1/0 | 53.5 | 133 | 10.98 | 2.79 | 4 | 8 | 5.59 | 52.8 | 4,767 | 317 | 211 |
2/0 | 67.4 | 133 | 12.68 | 2.79 | 3 | 8 | 5.59 | 55.9 | 5,514 | 335 | 243 |
3/0 | 85 | 259 | 13.89 | 2.79 | 2 | 8 | 5.97 | 59.9 | 6,490 | 359 | 279 |
4/0 | 107 | 259 | 15.79 | 2.79 | 1 | 8 | 5.97 | 63.5 | 7,556 | 381 | 321 |
250 | 127 | 259 | 16.84 | 3.05 | 1/0 | 8 | 6.35 | 68.3 | 8,850 | 410 | 355 |
350 | 177 | 259 | 20.24 | 3.05 | 2/0 | 8 | 6.73 | 74.9 | 11,120 | 449 | 435 |
500 | 253 | 259 | 23.92 | 3.05 | 4/0 | 8 | 7.11 | 84.1 | 14,886 | 505 | 536 |
CABLE TYPE SHD-GC 8 kV | |||||||||||
Conductor Size |
Nominal Area |
No. Threads Minimum |
Conductor Diameter |
Insulation Thickness |
Grounding Conductor Size |
Control Conductor Size |
Jacket Thickness |
OD Nominal |
Approx. Total Weight |
Min. Bending Radius |
Ampacity |
AWG / MCM | mm2 | mm | mm | AWG | AWG | mm | mm | kg / km | mm | A | |
4 | 21.2 | 49 | 6.82 | 3.81 | 8 | 8 | 5.21 | 49.3 | 3,397 | 394 | 122 |
3 | 26.7 | 49 | 7.77 | 3.81 | 7 | 8 | 5.21 | 51.3 | 3,786 | 410 | 140 |
2 | 33.6 | 133 | 8.68 | 3.81 | 6 | 8 | 5.59 | 53.8 | 4,223 | 430 | 159 |
1 | 42.4 | 133 | 9.83 | 3.81 | 5 | 8 | 5.59 | 56.1 | 4,745 | 449 | 184 |
1/0 | 53.5 | 133 | 10.98 | 3.81 | 4 | 8 | 5.59 | 58.9 | 5,373 | 471 | 211 |
2/0 | 67.4 | 133 | 12.68 | 3.81 | 3 | 8 | 5.97 | 62.5 | 6,211 | 500 | 243 |
3/0 | 85 | 259 | 13.89 | 3.81 | 2 | 8 | 6.35 | 66.5 | 7,218 | 532 | 279 |
4/0 | 107 | 259 | 15.79 | 3.81 | 1 | 8 | 6.35 | 69.9 | 8,276 | 559 | 321 |
250 | 127 | 259 | 16.84 | 3.81 | 1/0 | 8 | 6.35 | 73.4 | 9,396 | 587 | 355 |
350 | 177 | 259 | 20.24 | 3.81 | 2/0 | 8 | 7.11 | 81.3 | 11,913 | 650 | 435 |
500 | 253 | 259 | 23.92 | 3.81 | 4/0 | 8 | 7.49 | 90.4 | 15,686 | 723 | 536 |
CABLE TYPE SHD-GC 15 kV | |||||||||||
Conductor Size |
Nominal Area |
No. Threads Minimum |
Conductor Diameter |
Insulation Thickness |
Grounding Conductor Size |
Control Conductor Size |
Jacket Thickness |
OD Nominal |
Approx. Total Weight |
Min. Bending Radius |
Ampacity |
AWG / MCM | mm2 | mm | mm | AWG | AWG | mm | mm | kg / km | mm | A | |
2 | 33.6 | 133 | 8.68 | 5.33 | 6 | 8 | 5.97 | 61.2 | 5,210 | 490 | 164 |
1 | 42.4 | 133 | 9.83 | 5.33 | 5 | 8 | 5.97 | 64.0 | 5,849 | 512 | 187 |
1/0 | 53.5 | 133 | 10.98 | 5.33 | 4 | 8 | 6.35 | 67.1 | 6,580 | 537 | 215 |
2/0 | 67.4 | 133 | 12.68 | 5.33 | 3 | 8 | 6.35 | 69.3 | 7,272 | 554 | 246 |
3/0 | 85 | 259 | 13.89 | 5.33 | 2 | 8 | 6.73 | 73.7 | 8,420 | 590 | 283 |
4/0 | 107 | 259 | 15.79 | 5.33 | 1 | 8 | 6.73 | 77.5 | 9,616 | 620 | 325 |
We are China 2kV Up To 25kV Special Cables Mining Power Cable EPR Insulation Braided Metallic Shield manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.