2 Core Fire Retardant Cable Fireproof Electrical Cable For Alarm System
2 Core Fire Retardant Cable Fireproof Electrical Cable For Alarm System image
Brand Name :
Huanghe
Certification :
ISO OHSAS CCC
Place of Origin :
China
MOQ :
200
Payment Terms :
L/C, T/T, Western Union
Supply Ability :
50000 per week
Delivery Time :
5-8 days
Packaging Details :
Wooden drum
Application :
Mining,Alarm system and Signaling
Insulation material :
Fiberglass
Conductor material :
copper
Type :
Insulated
Conductor type :
Stranded,flexible
Color :
black and others
2 Core Fire Retardant Cable Fireproof Electrical Cable For Alarm System
This 0.6/1kV plastic insulated fire-resistant power cable is our qualified product, and it can offer fire proofing performance. It is resistant to fire and high temperature, so it can still work safely for some time even if fire takes place. Meanwhile, the conductor uses fire-proof tape which can relieve or stop the fire caused by the heat generated during the long time working. Thus, this product is suitable for place that highly requires fire resistant performance.
1. Conductors
The conductors shall be either of Class 1 or Class 2 of plain or metal-coated annealed copper or of plain aluminium or aluminium alloy, or of Class 5 of plain or metal-coated copper in accordance with IEC 60228.
2. Insulation
XLPE material and thickness shall be as per IEC 60502 or BS 5467 rated for 90°C continuous operation.
3. Assembly / Inner Covering
The inner coverings may be extruded or lapped. For cables with circular cores, except cables with more than five cores, a lapped inner covering shall be permitted only if the interstices between the cores are substantially filled. A suitable binder is permitted before application of an extruded inner covering. The material is compatible with the insulating material,The materials used for inner coverings and fillers shall be suitable for the operating temperature of the cable and compatible with the insulating material.For halogen free cables, the inner covering and fillers shall also be halogen free compound.
4. Armour
Aluminum/galvanized steel/steel wires applied helically over the Inner Covering as per IEC 60502-1, or double aluminum/steel tapes and copper/tinned copper wire can also be manufactured upon request.
5. Outer Sheath
Outer sheath shall be of extruded PVC Type ST1/ST2 as per IEC 60502-1, Polyethylene type ST3/ST7, Halogen free compound ST8, Polychloroprene, chlorosulfonated polyethylene or similar polymers, type SE1 are also available on request.
6. Fire Performance of Cable Sheaths
Cables can be supplied with special flame retardant PVC outer sheath to comply with the flame test requirements of IEC 60332-3-22, IEC 60332-3-23 and IEC 60332-3-24, Halogen Free material comply to IEC60754-1/2 and IEC 60684
2 core fire resistant cable fire rated electrical cable Fire resistant cable
del | Nominal Cross Section (mm2) | ||||
Single Core |
Two Core |
Three Core |
Four Core |
Five Core |
|
NH-VV NH-YJV | 1.5-800 | 1.5-800 | 1.5-800 | 1.5-800 | 1.5-800 |
NH-VV22 NH-YJV22 | 6-400 | 4-300 | 4-300 | 4-300 | 4-300 |
NH-VV32 NH-YJV32 | 10-800 | 4-300 | 4-300 | 4-300 | 4-300 |
We are China 2 Core Fire Retardant Cable Fireproof Electrical Cable For Alarm System manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Tags: Fire Resistant Cable, fire retardant cable, flame retardant wire