12.7/22(24)KV 3Cx185sqmm Multi XLPE Insulation Cable 12/20(24)KV IEC60502-2

 China 12.7/22(24)KV 3Cx185sqmm Multi XLPE Insulation Cable 12/20(24)KV IEC60502-2 supplier

12.7/22(24)KV 3Cx185sqmm Multi XLPE Insulation Cable 12/20(24)KV IEC60502-2 image

Get a Quote Email to us

Brand Name :Zhenglan Cable
Model Number :12.7/22(24)KV 3Cx240sqmm tripolar medinum voltage power cable 12/20(24)KV xlpe insulated power cable
Certification :3C; ISO 9001:2015, ISO 14001:2005, OHSAS 18001:2007
Place of Origin :Henan, China
MOQ :1500m
Price :Negotiable
Payment Terms :L/C, T/T,
Delivery Time :15 workdays for bulk order
Packaging Details :Wooden drum, wood and steel drum,as customer’s request
Material :aluminum
Out Sheath Color :Black
Core :3 core
Cable Drum Length :as per request
charactered :non armored
Specification :al/xlpe/cts/pvc
Name :12.7/22(24)KV 3Cx185sqmm tripolar medinum voltage power cable 12/20(24)KV xlpe insulated power cable
Referece standard :IEC60502-2

12.7/22(24)KV 3Cx185sqmm Multi Medium Voltage Power Cables 12/20(24)KV XLPE Insulation cable IEC60502-2

​APPLICATIONS:

12.7/22(24)KV 3Cx240sqmm tripolar medinum voltage power cable 12/20(24)KV xlpe insulated power cable are designed for distribution of electrical power with nominal voltage Uo/U ranging from 6.35/11(12)KV and frequency 50Hz. They are suitable for installation mostly in power supply stations, indoors and in cable ducts, outdoors, underground and in water as well as for installation on cable trays for industries, switchboards and power stations.

STANDARD:

IEC 60502 Part 2(3.6/6KV to 18/30KV), BS 6622, BS 7835 (LSZH Version)

Cable Construction

We adopt highly specialized plant, state-of-the-art research facilities and meticulous quality control procedures that are required for the manufacturing of xlpe insulated cables for use up to 6KV and XLPE insulated cables for use at voltages up to 35 KV.

Conductor

Number of conductors:1,3

The conductors shall comply with the requirement given in IEC

Insulation

XLPE(Cross-linked Polyethylene) according to IEC

Sheath

PVC(Polyaluminium Chloride) according to IEC

Metal screen

Copper Tape Screen

Galvanized tape armoured (SWA/STA)

Sheath colour: Black
Underground cable

Product features

XLPE insulated cables
Voltage: Up to 35KV

Conductor temperature

Maximum conductor temperature in normal use: 90℃

Max.short-circuit temperature

Maximum shall not exceed 250℃(5s Max,Duration)

Installation temperature

Ambient temperature under installation shall not be below 0℃

Minimum bending radius

The bending radius of cable: (D-Diameter of cable)

For Three Core Cable————————————-≥15D

For Single Core Cable————————————-≥20D

Technical parameters

Three Core 12.7/22KV (Um=24KV) Dimensional Data as per BS 6622/BS 7835

Nom. Cross- Section

Area

Nom. Insulation Thickness

Metallic Tape Screen Area

Nom.Bedding Thickness

Nom. Armour Wire Diameter

Nom. Sheath Thickness

Approx. Overall Diameter Approx. Weight
CU AL
mm² mm mm² mm mm mm mm kg/km
50 5.5 16 1.5 2.5 2.9 62.3 7710 6810
70 5.5 16 1.6 2.5 3.0 66.5 8710 7370
95 5.5 16 1.7 2.5 3.2 71.2 10000 8130
120 5.5 16 1.7 3.15 3.3 77.1 12040 9730
150 5.5 25 1.8 3.15 3.4 80.8 13550 10750
185 5.5 25 1.9 3.15 3.6 86.3 15150 11610
240 5.5 25 2.0 3.15 3.7 92.3 17710 12840
300 5.5 25 2.0 3.15 3.9 98.0 20170 14360
400 5.5 35 2.2 3.15 4.1 105.2 24520 16480

Three core 12/20kv without armor as per IEC60502-2

Normal cross sectional area(mm²) Appro conductor dia(mm) Nom insulation thickness(mm) Copper tape thickness(mm) Copper wire screen area(mm²) Appro. Insulation dia(mm) Nom sheath thickness(mm) Appro overall diameter(mm) Appro weight(kg/km)
CU AL
mm2 mm mm mm mm mm mm mm Kg/km Kg/km
35 7.10 5.5 0.1 16 19.7 1.8 53 3800 3100
50 8.25 5.5 0.1 16 20.9 1.8 56 4400 3500
70 9.90 5.5 0.1 16 22.5 1.8 60 5300 4000
95 11.7 5.5 0.1 16 24.3 1.8 64 6400 4600
120 13.1 5.5 0.1 16 25.7 2.0 67 7400 5200
150 14.3 5.5 0.1 25 26.9 2.0 70 8500 5700
185 16.3 5.5 0.1 25 28.9 2.1 75 10000 6500
240 18.7 5.5 0.1 25 31.3 2.1 80 12200 7500
300 20.9 5.5 0.1 25 33.5 2.2 85 14400 8700
400 23.7 5.5 0.1 35 36.3 2.3 91 17500 10200

Products show

Cable testing

Why Choose Zhenglan Cable:

  • OEM/ODM services provided;
  • Products comply with GB, IEC, BS, ASTM, DIN, VDE and JIS standards; Customer standard requirments Accepted;
  • Certified to ISO 9001:2015, ISO 14001:2015 and OHSAS 18001:2007;
  • Registered capital of $30 million and factory covers an area of 60,000㎡;
  • Advanced test equipment and procedures, 100% inspection before factory;
  • Enough stocks and the higest efficient shipping time guarranteed;
  • Professional pre-sales and after-sales services provided.

FAQ
1. Is your company a factory or a trade company?
Factory, more than 20 years in China

2. How long can I expect to get the sample?
After you pay the freight charge and send us confirmed files, the samples will be ready for delivery in 3-7 days. The samples will be sent to you via express and arrive in 3~7 days. You can use your own express account or prepay us if you do not have an account.

3. What are your payment terms?
We normally accept T/T 30% deposit, 70% balance before delivery as the main payment terms, and other payment can also be negotiated. Trade assurance on Alibaba is also available.

4. What’s the delivery time?
Sample order needs 3~5 days. Formal order depends on the quantity. Usually it needs 7-30 days after get your payment.

5. What is your MOQ?
Generally for medinum voltage poer cable MOQ is 1000m.

We are China 12.7/22(24)KV 3Cx185sqmm Multi XLPE Insulation Cable 12/20(24)KV IEC60502-2 manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION