10mm2 PVC Insulated Single Phase Concentric Cable Black PVC Outer Sheath

 China 10mm2 PVC Insulated Single Phase Concentric Cable Black PVC Outer Sheath supplier

10mm2 PVC Insulated Single Phase Concentric Cable Black PVC Outer Sheath image

Get a Quote Email to us

Brand Name :
Yifang Cable

Model Number :
10mm2 concentric cable

Certification :
ISO

Place of Origin :
China

MOQ :
10km

Price :
depending on current material price

Payment Terms :
L/C, T/T, Western Union, MoneyGram

Supply Ability :
15000km/year

Delivery Time :
5-8 working days

Packaging Details :
Wooden Drum

Product name :
10 mm2 PVC insulated single phase concentric Aluminum cable without two core copper communication cable

Conductor :
Aluminum

Insulation :
PVC

Insulation color :
Red

Neutral conductor :
Aluminum Wire

Outer sheath :
Black PVC

Neutral conductor sectional area :
10mm2

Standard :
KS 04-1022 IEC 60502-1

10 mm2 PVC insulated single phase concentric Aluminum cable without two core copper communication cable

Guaranteed Technical Particulars

(10mm2 PVC Insulated Single Phase Concentric Aluminium Cable without Two core Copper Communication Cable)

Clause Number KPLC Requirement Bidder’s Offer

Manufacturer’s Name and address

Zhengzhou Yifang Cable Co.Ltd./ No.7, Changchun Road, High-Tech. Industry Area, Zhengzhou, China
Country of Manufacture China
Bidder’s Name and address

KENYA

1. Scope

KP1/6C/13/TSP/05/033

1.1-1.3
2. Applicable Standards BS7870,BS6746, KS04-1022
3. Terms&Definitions For the purpose of this specification the definitions given in the reference standards shall apply
4. Requirements
4.1 Service Conditions The cable shall be a service cable for continuous operation outdoors and tropical conditions(temperature rang of -1℃ to +40℃, humidity of upto 90% and saline conditions along the coast),suitable for laying in cable ducts and in air,permissible continuous loading operating temperature shall be 70℃ and short circuit temperature of 160℃.
4.2 Materials&Construction
4.2.1 General requirements BS 7870-3.20:2001 and Kenya Standard KS 04-1022 BS 7870-3.20:2001 and Kenya Standard KS 04-1022
4.2.2 Phase conductor (Material & construction)
4.2.2.1 Typical construction Material Circular stranded plain annealed aluminum Conductor Left Hand
Direction of lay
4.2.2.2 Insulation As per KS 04-1022. KS 04-188 and BD 6746 As per KS 04-1022. KS 04-188 and BD 6746
4.2.2.3 Thickness of insulation As per KS 04-1022 Min.1.55mm
4.2.3 Concentric layer
4.2.3.1 Neutral earth conductor (Material & construction)
4.2.3.1.1 Typical construction Material Plain annealed aluminum wire
Number of wires and the resistance of the earth-neutral conductors 7, 3.08Ω/KM
4.2.3.1.2 Direction of lay Right Hand
4.2.3.2 Communication cable
4.2.3.2.1 Construction
4.2.3.2.1.1
4.2.3.2.1.2 Material As per BS 6360 and BS 2011, Test 2T, Method 1 /
4.2.3.2.1.3 Length of lay /
Direction of lay of the strand
4.2.3.2.1.4 Joints Shall be essentially smooth, and shall not have any sharp projections /
4.2.3.2.1.5 Colors Correspond with standard colours shown in IEC 60304:1982 /
4.2.3.2.2 Insulation /
Material PVC compound-type TI1 as specified in KS 04-1022, KS 04-188 and BS 6746 /
Dimensions As per table 2 /
4.2.4 Over-sheath or Outer Jacket
4.2.4.1 Material As per KS 04-1022 and BS 6746 As per KS 04-1022 and BS 6746
Oversheath testing In accordance with KS 04-1022 In accordance with KS 04-1022
4.2.4.2 Minimum thickness Shall not fall below the values on Table 2 by>(15%+0.1mm) 0.31mm
4.2.4.3 Non-metallic rip-cord Shall be laid under the sheath Yes
Shall incorporate the manufacturer’s identification colour
4.3 Standard sizes and characteristics As per table 2, Table 3 and as per the requirement of clause 4 of BS 7870-3.20:2001 As reqired
4.4 Embossing on cable Oversheath (parameters to be indicated and method of marking)

4.5

Quality Management System Yes
Quality Assurance Plan Yes
Copy of ISO 9001:2008 Certificate Yes
Manufacturer’s experience Yes
Manufacturing Capacity (units per month) Yes
List of previous customers Yes
Customer reference letters Yes
5.1 Test standards and responsibility of carrying out tests KS 04-1022, BS 7870-3.20, BS 6746,BS4804-1,BS6360
5.2 Copies of Type Test Reports submitted with tender Yes
5.3 Acceptance testes to be witnessed by KPLC at factory before shipment Yes
5.4 Test reports to be submitted by supplier to KPLC for approval before shipment Yes
5.5 Replacement of rejected cables Yes
6.1 Markings As required
6.2 Packing Wooden Drum
7.1 Documents submitted with tender Yes
7.2 Documents to be submitted by supplier to KPLC for approval before manufacture Yes