1.8mm,2.5mm,3.0mm,3.2mm,3.5mm,4.0mm.4.8mm Galvanized Steel Core Wire for ACSR Conductor
1.8mm,2.5mm,3.0mm,3.2mm,3.5mm,4.0mm.4.8mm Galvanized Steel Core Wire for ACSR Conductor image
Brand Name :
LITONG GLOBAL
Model Number :
LT-161216
Certification :
ISO9001-2008
Place of Origin :
ANHUI,CHINA
MOQ :
10tons
Price :
US$1-1200/ton
Supply Ability :
400tons/day
Packaging Details :
Standard export seaworthy packing
Material :
High Carbon Steel Wire
Surface treatment :
Hot-dipped Galvanized
Main size :
1.0mm-4.8mm
Main construction :
1*7,1*19
Main production Standard :
ASTM B 498/475,IEC888,BS183,JISG GB/T
Packing :
Standard export seaworthy packing in coil
Loading capacity :
25tons/20″
Description
Our galvanized stranded wires provide a combination of superior properties compared to conventional six strand ropes. With compacted structure and smooth face, this 1*7 galvanized stranded wire provides enhanced durability and resistance to abrasion and crushing, and improves the service life.
Construction & Diameter: 1*7/4.8-12.7 mm
Features
1. The galvanized stranded wire offers a smooth and polished surface.
2. It offers excellent antirust performance.
3. It is adhesive and flexible.
Application
Our 1*7 galvanized stranded wire can be used as messenger wires, guy wires, core wires or strength members, earth wires/ground wires, barrier cables, structure cables, messenger wires for optical fiber cable, etc.
As a professional 1*7 galvanized stranded wire manufacturer and supplier based in China, We also offers1*3, 1*19 galvanized stranded wire, 12.70mm PC strand, 2.0mm and 2.64mm galvanized steel wire, among others.
EN 50189 Standard
Table 1. Initial Settings for Determining Stress 1% Extension | |||
Nominal Wire Diameter, mm | Initial Stress, N/mm2 | Initial setting of extensometer for a gauge length of 250mm2 | |
1.24 | 2.25 | 100 | 0.125 |
2.25 | 3 | 200 | 0.25 |
3 | 4.75 | 300 | 0.375 |
4.75 | 5.5 | 400 | 0.5 |
For other gauge lengths, multiply the initial setting by the gauge length in mm divided by 250. |
Table 2. Zinc Coating Requirements | |||||||||||
Nominal Wire Diameter, mm | Class A | Class B | Class C | Class D | Class E | ||||||
Over | Up to and incl. | Min. mass of Zn g/m2 | Min. no. of one minute dips | Min. mass of Zn g/m2 | Min. no. of one minute dips | Min. mass of Zn g/m2 | Min. no. of one minute dips | Min. mass of Zn g/m2 | Min. no. of one minute dips | Min. mass of Zn g/m2 | Min. no. of one minute dips |
1.24 | 1.5 | 185 | 2 | 370 | 3.5 | 150 | 1 | 365 | 3 | 185 | 2 |
1.5 | 1.75 | 200 | 2 | 400 | 3.5 | 160 | 1.5 | 460 | 3.5 | 200 | 2 |
1.75 | 2 | 215 | 2.5 | 430 | 4 | 175 | 2 | 550 | 4 | 215 | 2.5 |
2 | 2.25 | 215 | 2.5 | 430 | 4 | 175 | 2 | 550 | 4 | 250 | 3.5 |
2.25 | 2.75 | 230 | 3 | 460 | 4 | 190 | 2.5 | 640 | 5 | 250 | 3.5 |
2.75 | 3 | 230 | 3 | 460 | 4 | 190 | 2.5 | 640 | 5 | 250 | 3.5 |
3 | 3.5 | 245 | 3.5 | 490 | 4 | 205 | 3 | 730 | 6 | 250 | 3.5 |
3.5 | 4.25 | 260 | 3.5 | 520 | 4 | 260 | 3.5 | 730 | 6 | 260 | 3.5 |
4.25 | 4.75 | 275 | 4 | 550 | 4 | 275 | 4 | 775 | 6 | 275 | 4 |
4.75 | 5 | 200 | 4 | 580 | 5 | 290 | 4 | 825 | 6 | 290 | 4 |
5 | 5.25 | 290 | 4 | 580 | 5 | 290 | 4 | 825 | 6 | 290 | 4 |
5.25 | 5.5 | 290 | 4 | 580 | 5 | 290 | 4 | 825 | 6 | 290 | 4 |
Table 3. Mechanical Properties of ST1A Wires | |||||||
Nominal wire diameter mm | Diameter tolerance | Stress at 1% extension, MPa | Tensile strength, MPa | Elongation on 250mm | Mandrel diameter for wrapping test | No. of torsion twists | |
Over | Up to and incl. | mm | N/MM2 | N/MM2 | % | ||
Min. | Min. | Min. | xd | Min. | |||
1.24 | 1.5 | ±0.03 | 1170 | 1400 | 3 | 1 | 18 |
1.5 | 1.75 | ±0.03 | 1170 | 1400 | 3 | 1 | 18 |
1.75 | 2.25 | ±0.03 | 1170 | 1400 | 3 | 1 | 18 |
2.25 | 2.75 | ±0.04 | 1140 | 1350 | 3 | 1 | 16 |
2.75 | 3 | ±0.05 | 1140 | 1350 | 3.5 | 1 | 16 |
3 | 3.5 | ±0.05 | 1100 | 1300 | 3.5 | 1 | 14 |
3.5 | 4.25 | ±0.06 | 1100 | 1300 | 4 | 1 | 12 |
4.25 | 4.75 | ±0.06 | 1100 | 1300 | 4 | 1 | 12 |
4.75 | 5.5 | ±0.07 | 1100 | 1300 | 4 | 1 | 12 |
Table 4. Mechanical properties of ST2B Wires | ||||||
Nominal wire diameter mm | Diameter tolerance | Stress at 1% extension, MPa | Tensile strength, MPa | Elongation on 250mm | Mandrel diameter for wrapping test | |
Over | Up to and incl. | mm | N/MM2 | N/MM2 | ||
1.24 | 1.5 | ±0.05 | 1100 | 1300 | 4 | 1 |
1.5 | 1.75 | ±0.05 | 1100 | 1300 | 4 | 1 |
1.75 | 2.25 | ±0.05 | 1100 | 1300 | 4 | 1 |
2.25 | 2.75 | ±0.06 | 1070 | 1250 | 4 | 1 |
2.75 | 3 | ±0.06 | 1070 | 1250 | 4 | 1 |
3 | 3.5 | ±0.07 | 1000 | 1200 | 4 | 1 |
3.5 | 4.25 | ±0.09 | 1000 | 1200 | 4 | 1 |
4.25 | 4.75 | ±0.10 | 1000 | 1200 | 4 | 1 |
4.75 | 5.5 | ±0.11 | 1000 | 1200 | 4 | 1 |
Other Products
BS4565-1990 Standard
Table 1. Initial Settings for Determining Stress 1% Extension | |||
Nominal Diameter of Galvanized Steel Wire | Initial Stress N/mm2 | Initial Setting of Extensometer mm/mm | |
> | < | ||
mm | mm | ||
1.18 | 2.24 | 95 | 0.05 |
2.24 | 3.15 | 190 | 0.10 |
3.15 | 5.00 | 285 | 0.15 |
Table 2. Tensile Strength and Stress at 1% Elongation | |||
Nominal Diameter of Galvanized Steel Wire | Tensile Strength minimum N/mm2 | Stress at 1% elongation minimum N/mm2 | |
> | < | ||
mm | mm | ||
1.18 | 2.24 | 1400 | 1180 |
2.24 | 3.15 | 1320 | 1140 |
3.15 | 5.00 | 1320 | 1100 |
Table 3. Properties for High Strength Galvanized Steel Wire for ACSR | ||||||||||
Tensile strength grade N/mm2, min. | 1550 | 1700 | 1800 | |||||||
Nominal diameter of galvanized wire | Min. stress at 1% elongation | Min. elongation L0+=200mm% | Steel wrap test dia. | Min. stress at 1% elongation | Min. elongation L0+=200mm% | Steel Wrap test dia. | Min. stress at 1% elongation | Min. elongation L0+=200mm% | Steel wrap test dia. | |
> | ≤ | |||||||||
mm | mm | |||||||||
1.18 | 1.32 | 1260 | 3.0 | 1d | 1320 | 3.0 | 2d | 1370 | 3.0 | 3d |
1.32 | 1.80 | 1260 | 3.5 | 1d | 1320 | 3.0 | 2d | 1370 | 3.0 | 3d |
1.80 | 2.24 | 1260 | 3.5 | 2d | 1320 | 3.0 | 2d | 1370 | 3.0 | 3d |
2.24 | 2.72 | 1260 | 3.5 | 2d | 1320 | 3.5 | 3d | 1370 | 3.0 | 3d |
2.72 | 2.90 | 1260 | 3.5 | 2d | 1320 | 3.5 | 3d | 1370 | 3.0 | 3d |
2.90 | 4.00 | 1220 | 4.0 | 3d | 1280 | 3.5 | 3d | – | – | – |
4.00 | 5.00 | 1220 | 4.0 | 3d | – | – | – | – | – | – |
d=Nominal diameter of galvanized wire | ||||||||||
L0= Original Gauge Length |
Table 4. Conversions of Tensile Strength and Stress at 1% Elongation | |
N/MM2 | tonf/in2 |
1100 | 71.2 |
1140 | 73.8 |
1180 | 76.4 |
1220 | 79.0 |
1260 | 81.6 |
1280 | 82.9 |
1320 | 85.5 |
1370 | 88.7 |
1400 | 9.07 |
1550 | 100.4 |
1700 | 110.1 |
1800 | 116.6 |
ASTMB498B/498M-2002 Standard
Table 1. Zinc Coating | |||
Specified Diameter of Coated Wre | Class A | Class C | |
1.6-1.9 | 210 | 630 | |
>1.9-2.3 | 220 | 440 | 660 |
>2.3-2.7 | 230 | 460 | 690 |
>2.7-3.1 | 240 | 480 | 720 |
>3.1-3.5 | 260 | 520 | 780 |
>3.5-3.9 | 270 | 540 | 810 |
>3.9-4.5 | 275 | 550 | 825 |
>4.5-4.8 | 300 | 600 | 900 |
Table 2. Tensile Requirements | |||||||||
Specified Diameter | Stress at 1 % Extension min Mpa | Ultimate Tensile Strength min MPA | Elongation in 250mm, min, 1% | ||||||
Class A | Class B | Class C | Class A | Class B | Class C | Class A | Class B | Class C | |
1.6-2.3 | 1310 | 1240 | 1170 | 1450 | 1380 | 1310 | 3 | 3 | 3 |
>2.3-3.05 | 1280 | 1210 | 1140 | 1410 | 1340 | 1280 | 3.5 | 3 | 3 |
>3.05-3.6 | 1240 | 1170 | 1100 | 1410 | 1340 | 1280 | 4 | 3 | 3 |
>3.6-4.8 | 1170 | 1100 | 1070 | 1380 | 1280 | 1240 | 4 | 4 | 4 |
Table 3. Initial Settings for Determining Stress 1% Extension | ||
Specified Diameter, mm | Initial Stress, MPA | Initial Setting of Extensometer, mm/mm |
1.6-2.3 | 100 | 0.0005(0.05% extension) |
>2.3-3.05 | 190 | 0.0010(0.10% extension) |
>3.05-4.8 | 290 | 0.0015(0.15% extension) |
Table 4. Mandrel Size for Adherence Test | |
Specified Wire Diameter,mm | Ratio of Mandrel Diameter to Wire Diameter |
1.6-2.3 | 3 |
>2.3-3.05 | 4 |
>3.05-4.8 | 5 |
Table 5. Permissible Variations in Diameter of Zinc-Coated Steel Wire | ||
Specified Diameter, mm | Permissible Variation, mm | |
Plus | Minus | |
1.6-2.3 | 0.04 | 0.03 |
>2.3-3.05 | 0.05 | 0.05 |
>3.05-3.6 | 0.08 | 0.05 |
>3.6-4.8 | 0.1 | 0.08 |
Other Products
ASTM A475 Standard
Dia. of strand, in(mm) | Minimum Breaking Strength of Strand,1bf(kN) | Weight of Zine Coating, g/m2 | |
High Strength Grade | Extra High Strength Grade | CLASS A | |
3/16(4.76) | 2850(12.677) | 3990(17.748) | 153 |
1/4(6.35) | 2850(21.129) | 6650(29.581) | 183 |
5/16(7.94) | 8000(35.586) | 11200(49.820) | 244 |
3/8(9.52) | 10800(48.040) | 15400(68.503) | 259 |
7/16(11.11) | 14500(64.499) | 20800(92.523) | 275 |
1/2(12.70) | 18800(83.627) | 26900(119.657) | 275 |
ASTM B498 Standard
Dia of Wire, mm | Tensile Strength, Mpa | Stress at 1% Extension, Mpa | Coating, g/m2 | |
CLASS A | CLASS B | |||
0.80-1.57 | 1000-1550 | / | 50-153 | / |
1.57-1.90 | 1000-1550 | / | 153-210 | / |
1.90-2.30 | 1000-1550 | 1310 | 220 | 440 |
2.30-2.70 | 1000-1550 | 1280 | 230 | 460 |
2.70-3.10 | 1000-1550 | 1280 | 240 | 480 |
3.10-3.50 | 1000-1550 | 1240 | 260 | 520 |
3.50-3.90 | 1000-1550 | 1170 | 270 | 540 |
3.90-4.50 | 1000-1550 | 1170 | 275 | 550 |
4.50-4.80 | 1000-1550 | 1170 | 300 |
Welcome to enquiry our Galvanized steel wire.
Nancy
what'app:0086-13855514957
Skype:nancylsl
E-mail:[email protected]
We are China 1.8mm,2.5mm,3.0mm,3.2mm,3.5mm,4.0mm.4.8mm Galvanized Steel Core Wire for ACSR Conductor manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Tags: Galvanized Steel WireFAST AND RELIABLE SERVICE FOR YOUR PROJECT
Contact our trained experts today to find your perfect power solution.
ASK A QUESTION© 2020 Galaxy Electric Country Code Sitemap Cable Cable Drum