0.6 / 1kV LV Aerial Bundled Conductor Low Voltage Power Cable AL Material

 China 0.6 / 1kV LV Aerial Bundled Conductor Low Voltage Power Cable AL Material supplier

0.6 / 1kV LV Aerial Bundled Conductor Low Voltage Power Cable AL Material image

Get a Quote Email to us

Brand Name :
Zhenglan cable

Model Number :
0.6/1KV

Certification :
ISO 9001:2015, ISO 14001:2005, OHSAS 18001:2007

Place of Origin :
Henan, China

MOQ :
300 meters

Payment Terms :
L/C, T/T, Western Union

Supply Ability :
10000m/day

Delivery Time :
10 days

Packaging Details :
Wooden drum, wood and steel drum,as customer’s request

Material :
AL

Insulation :
xlpe

Out Sheath Color :
Black or Customized

Core :
4

Cable Length :
as per requirement

Voltage :
0.6/1kv

Character :
Unarmoured

sheath :
pvc

0.6/1kV LV Aerial Bundled Conductor Cables/ ABC Cable /4 Cores Overhead Cable

APPLICATION

Aerial Bundle Cable (ABC cable) is a very innovative concept for overhead power distribution as compared to the conventional bare conductor overhead distribution system. It provides higher level of safety and reliability, lower power losses and ultimate system economy by reducing installation, maintenance and operative cost.

Caledonian LV Aerial Bundle Cables are designed to supply 600/1000 volt aerial service for temporary service at construction sites, as a service drop (power pole to service entrance), as a secondary cable (pole to pole) or street lighting. This over-head cable provides reinforced insulation acc. IEC 61140 and fulfill therefore Class II acc. IEC 61140. It is not flame retardant. But this could be if requested change to a flame retardant cable.

STANDARD

Basic design to BS 7870 / TNB Specification (IEC 60502) / HD 626 S1 / NFC 33-209 / AS/ NZS 3560-1 standards.

CONSTRUCTION

Conductor: Aluminium conductor, round stranded compressed (RM).

insulation: XPLE compound, UV-resistant.

Core identification: 1, 2 resp. 3 raised longitudinal ribs on the surface of the cores. The surface of the neutral core should have at least 12 ribs for cross-sections up to 50 mm² and a minimum of 16 ribs for cores above 50 mm². In the case of five core bundles the surface of the protective core should be smooth.

ELECTRICAL PROPERTIES

Rated Voltage 0.6/1kV
Test Voltage 4 Veff kV
Minimum laying Temperature -20°C
Operating Temperature -40°C~ +90°C
Maximum Short-circuit Temperature 250°C
Maximum Conductor Temperature 80°C
Minimum Bending radius 18×OD

CONSTRUCTION PARAMETERS

• TNB Specification (IEC 60502)

Number of Cores x Nominal Cross Section Overall Diameter Weight Maximum Conductor Resistance Minimum Breaking Load Current Rating
No.x mm2 mm Kg/Km Ω/Km KN A
3×16+1×25 RM 19.0 290 1,200 4,0 107
3×25+1×25 RM 23.2 400 0,868 5,5 132
3×35+1×25 RM 25.6 500 0,641 8,0 165
3×50+1×35 RM 30.0 680 0,443 10,7 205
3×70+1×50 RM 34.9 920 0,320 13,7 240
3×95+1×70 RM 40.6 1270 0,253 18,6 290
3×120+1×70 RM 44.1 1510 0,206 23,2 334
3×150+1×95 RM 49.2 1870 0,164 28,7 389
3×185+1×120 RM 54.9 2340 0,125 37,2 467
3×25+1×25+1×16 RM 23.2 470 1,910 2,5 72
3×35+1×25+1×16 RM 25.6 560 1,200 4,0 107
3×50+1×35+1×16 RM 30.0 740 0,868 5,5 132
3×70+1×50+1×16 RM 34.9 980 0,641 8,0 165
3×95+1×70+1×16 RM 40.6 1330 0,443 10,7 205
3×120+1×70+1x16RM 44.1 1580 0,320 13,7 240
3×150+1×95+1x16RM 49.2 1940 0,206 23,2 334
3×185+1×120+1x16RM 54.9 2410 1,910 2,5 72

Why Choose Zhenglan Cable:

  • OEM/ODM services provided;
  • Products comply with GB, IEC, BS, ASTM, DIN, VDE and JIS standards; Customer standard requirments Accepted;
  • Advanced test equipment and procedures, 100% inspection before factory;
  • Enough stocks and the higest efficient shipping time guarranteed;
  • Professional pre-sales and after-sales services provided.

We are China 0.6 / 1kV LV Aerial Bundled Conductor Low Voltage Power Cable AL Material manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Tags: , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION